Dose reduction potential in diagnostic single energy CT through patient-specific prefilters and a wider range of tube voltages.

Jörg Steidel, Joscha Maier, Stefan Sawall, Marc Kachelrieß

Abstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jörg SteidelMedical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld, Heidelberg, Germany.
Joscha MaierMedical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld, Heidelberg, Germany.
Stefan SawallMedical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld, Heidelberg, Germany.
Marc KachelrießMedical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld, Heidelberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVarious studies have demonstrated that additional prefilters and/or reduced tube voltages have the potential to significantly increase the contrast-to-noise ratios at unit dose (CNRDs) and thereby to significantly reduce patient dose in clinical CT. An exhaustive analysis, accounting for a wide range of filter thicknesses and a wide range of tube voltages extending beyond the 70 to 150 kV range of today's CT systems, including their specific choice depending on the patient size, is, however, missing. Therefore, this work analyzes the dose reduction potential for patient-specific selectable prefilters combined with a wider range of tube voltages. We do so for soft tissue and iodine contrast in single energy CT. The findings may be helpful to guide further developments of x-ray tubes and automatic filter changers.

methodsCT acquisitions were simulated for different patient sizes (semianthropomorphic phantoms for child, adult, and obese patients), tube voltages (35-150 kV), prefilter materials (tin and copper), and prefilter thicknesses (up to 5 mm). For each acquisition soft tissue and iodine CNRDs were determined. Dose was calculated using Monte Carlo simulations of a computed tomography dose index (CTDI) phantom. CNRD values of acquisitions with different parameters were used to evaluate dose reduction.

resultsDose reduction through patient-specific prefilters depends on patient size and available tube current among others. With an available tube current time product of 1000 mAs dose reductions of 17% for the child, 32% for the adult and 29% for the obese phantom were achieved for soft tissue contrast. For iodine contrast dose reductions were 57%, 49%, and 39% for child, adult, and obese phantoms, respectively. Here, a tube voltage range extended to lower kV is important.

conclusionsSubstantial dose reduction can be achieved by utilizing patient-specific prefilters. Tube voltages lower than 70 kV are beneficial for dose reduction with iodine contrast, especially for small patients. The optimal implementation of patient-specific prefilters benefits from higher tube power. Tin prefilters should be available in 0.1 mm steps or lower, copper prefilter in 0.3 mm steps or lower. At least 10 different prefilter thicknesses should be used to cover the dose optima of all investigated patient sizes and contrast mechanisms. In many cases it would be advantageous to adapt the prefilter thickness rather than the tube current to the patient size, that is, to always use the maximum available tube current and to control the exposure by adjusting the thickness of the prefilter.

Indexed as

Drug TaperingTomography, X-Ray ComputedAdultChildHumansMonte Carlo MethodPhantoms, ImagingRadiation Dosagecomputed tomographyimage qualityradiation dose reductionx-ray filtration

Identifiers

PMID34796532
PMCPMC13655647

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.