ArticleFrontiers in oncology2021
Evaluation of Daily CT for EPID-Based Transit
Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Quantitative evaluation of the effect of anatomical changes on the results of in vivo dosimetry during radiation therapy in the thoracic region.Journal of applied clinical medical physics · 2026Article
- Real-Time AI-Based Radiotherapy Planning for Nasopharyngeal Carcinoma: Development and Validation.Cyborg and bionic systems (Washington, D.C.) · 2026Article
- CycleGan-based kV-to-MV image translation for potential in vivo dosimetry application: concept proposal and cross-institutional validation.BMC medical imaging · 2025Article
- An all-in-one workflow for emergency hippocampal-avoidance whole-brain radiotherapy in brain metastases, with optional online adaptive extension.Journal of applied clinical medical physics · 2025Article
- Deep learning-based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices.Journal of applied clinical medical physics · 2025Article
- Evaluation of a Monte Carlo based EPID system for patient-specific IMRT and VMAT quality assurance.Journal of applied clinical medical physics · 2025Article
- Validation of in vivo dose using EPID combined with fan-beam CT guidance in post-breast-conserving radiotherapy for early-stage breast cancer.BMC cancer · 2025Article
- Risk assessment and quality management in AIO based on CT-linac for nasopharyngeal carcinoma: An improved FMEA and FTA approach.Medical physics · 2025Article
- Evaluating the Implementation of fan-beam CT-guided online adaptive re-planning in definitive cervical cancer radiotherapy.Frontiers in oncology · 2025Article
- Towards quantitative in vivo dosimetry using x-ray acoustic computed tomography.Medical physics · 2023Article
- The application of gradient dose segmented analysis of in-vivo EPID images for patients undergoing VMAT in a resource-constrained environment.Journal of applied clinical medical physics · 2023Article
- Fan beam CT-guided online adaptive external radiotherapy of uterine cervical cancer: a dosimetric evaluation.BMC cancer · 2023Article
- Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry.Physics and imaging in radiation oncology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe difference in anatomical structure and positioning between planning and treatment may lead to bias in electronic portal image device (EPID)-based MATERIALS AND
methodsTwenty patients were enrolled in this study. The study design included eight different sites (the cervical, nasopharyngeal, and oral cavities, rectum, prostate, bladder, lung, and esophagus). All treatments were delivered with a CT-linac 506c (UIH, Shanghai) using 6 MV photon beams. This machine is equipped with diagnosis-level fan-beam CT and an amorphous silicon EPID XRD1642 (Varex Imaging Corporation, UT, USA). A Monte Carlo algorithm was developed to calculate the transmit EPID image. A pretreatment measurement was performed to assess system accuracy by delivering based on a homogeneous phantom (RW3 slab, PTW, Freiburg). During treatment, each patient underwent CT scanning before delivery either once or twice for a total of 268 fractions obtained daily CT images. Patients may have had a position correction that followed our image-guided radiation therapy (IGRT) procedure. Meanwhile, transmit EPID images were acquired for each field during delivery. After treatment, all patient CTs were reviewed to ensure that there was no large anatomical change between planning and treatment. The reference of transmit EPID images was calculated based on both planning and daily CTs, and the IGRT correction was corrected for the EPID calculation. The gamma passing rate (3 mm 3%, 2 mm 3%, and 2 mm 2%) was calculated and compared between the planning CT and daily CT. Mechanical errors [ ± 1 mm, ± 2 mm, ± 5 mm multileaf collimator (MLC) systematic shift and 3%, 5% monitor unit (MU) scaling] were also introduced in this study for comparing detectability between both types of CT.
resultThe average (standard deviation) gamma passing rate (3 mm 3%, 2 mm 3%, and 2 mm 2%) in the RW3 slab phantom was 99.6% ± 1.0%, 98.9% ± 2.1%, and 97.2% ± 3.9%. For patient measurement, the average (standard deviation) gamma passing rates were 87.8% ± 14.0%, 82.2% ± 16.9%, and 74.2% ± 18.9% for using planning CTs as reference and 93.6% ± 8.2%, 89.7% ± 11.0%, and 82.8% ± 14.7% for using daily CTs as reference. There were significant differences between the planning CT and daily CT results. All p-values (Mann-Whitney test) were less than 0.001. In terms of error simulation, nonparametric test shows that there were significant differences between practical daily results and error simulation results (p < 0.001). The receiver operating characteristic (ROC) analysis indicated that the detectability of mechanical delivery error using daily CT was better than that of planning CT. AUC
conclusionThis study shows the feasibility and effectiveness of using two-dimensional (2D) EPID portal image and daily CT-based
Indexed as
Identifiers
What OpenQuestion holds
Registered trials