Evidence map›Paper›PMID 34793828›Full record

ArticleExperimental eye research2022

Open-source deep learning-based automatic segmentation of mouse Schlemm's canal in optical coherence tomography images.

Kevin C Choy, Guorong Li, W Daniel Stamer, Sina Farsiu

Open access · bronzeAbstract read
In one paragraph

Article in Experimental eye research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Kevin C ChoyDepartment of Biomedical Engineering, Duke University, Durham, NC, United States.
Guorong LiDepartment of Ophthalmology, Duke University, Durham, NC, United States.
W Daniel StamerDepartment of Biomedical Engineering, Duke University, Durham, NC, United States; Department of Ophthalmology, Duke University, Durham, NC, United States.
Sina FarsiuDepartment of Biomedical Engineering, Duke University, Durham, NC, United States; Department of Ophthalmology, Duke University, Durham, NC, United States. Electronic address: sina.farsiu@duke.edu.
Duke University · US

Funding

VISION RESEARCHP30EY005722 · NEI · DUKE UNIVERSITY · PI Vadim Y Arshavsky · 1985 to 2026
$19.3M
Quantitative assessment of glaucomatous conventional outflow dynamicsR01EY030124 · NEI · DUKE UNIVERSITY · PI C ROSS ETHIER, Sina Farsiu · 2019 to 2026
$4.0M
Transcriptional and Biomechanical Analysis of Segmental Outflow in GlaucomaR01EY031710 · NEI · GEORGIA INSTITUTE OF TECHNOLOGY · PI ETHIER, C ROSS, GUPTA, DIVAKAR · 2020 to 2023
$2.4M
NEI NIH HHS P30 EY005722NEI NIH HHS R01 EY030124NEI NIH HHS R01 EY031710
6 · The paper itself

Abstract

The purpose of this study was to develop an automatic deep learning-based approach and corresponding free, open-source software to perform segmentation of the Schlemm's canal (SC) lumen in optical coherence tomography (OCT) scans of living mouse eyes. A novel convolutional neural network (CNN) for semantic segmentation grounded in a U-Net architecture was developed by incorporating a late fusion scheme, multi-scale input image pyramid, dilated residual convolution blocks, and attention-gating. 163 pairs of intensity and speckle variance (SV) OCT B-scans acquired from 32 living mouse eyes were used for training, validation, and testing of this CNN model for segmentation of the SC lumen. The proposed model achieved a mean Dice Similarity Coefficient (DSC) of 0.694 ± 0.256 and median DSC of 0.791, while manual segmentation performed by a second expert grader achieved a mean and median DSC of 0.713 ± 0.209 and 0.763, respectively. This work presents the first automatic method for segmentation of the SC lumen in OCT images of living mouse eyes. The performance of the proposed model is comparable to the performance of a second human grader. Open-source automatic software for segmentation of the SC lumen is expected to accelerate experiments for studying treatment efficacy of new drugs affecting intraocular pressure and related diseases such as glaucoma, which present as changes in the SC area.

Indexed as

Deep LearningTomography, Optical CoherenceAlgorithmsAnimalsAnterior Eye SegmentGlaucoma, Open-AngleIntraocular PressureMiceMice, Inbred C57BLNeural Networks, ComputerScleraTonometry, OcularDeep learningGlaucomaImage segmentationOptical coherence tomographySchlemm's canal

Identifiers

PMID34793828
PMCPMC8792324
OpenAlexW3214472279

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.