Evidence map›Paper›PMID 34793558›Full record

ArticlePloS one2021

Comparison of VividTrac, King Vision and Macintosh laryngoscopes in normal and difficult airways during simulated cardiopulmonary resuscitation among novices.

Dóra Keresztes, Ákos Mérei, Martin Rozanovic, Edina Nagy, Zoltán Kovács-Ábrahám, János Oláh, Péter Maróti, Szilárd Rendeki, Bálint Nagy, Gábor Woth

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Dóra KeresztesDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.ORCID 0000-0002-0618-9890
Ákos MéreiDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.
Martin RozanovicMedical Skills Lab, Medical School, University of Pécs, Pécs, Hungary.
Edina NagyMedical School, University of Pécs, Pécs, Hungary.
Zoltán Kovács-ÁbrahámDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.
János OláhMedical School, University of Pécs, Pécs, Hungary.
Péter MarótiMedical Skills Lab, Medical School, University of Pécs, Pécs, Hungary.ORCID 0000-0001-7538-0675
Szilárd RendekiDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.
Bálint NagyDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.ORCID 0000-0002-4865-8958
Gábor WothDepartment of Anesthesiology and Intensive Therapy, Medical School, University of Pécs, Pécs, Hungary.
University of Pecs · HU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionEarly endotracheal intubation improves neurological outcomes in cardiopulmonary resuscitation, although cardiopulmonary resuscitation is initially carried out by personnel with limited experience in a significant proportion of cases. Videolaryngoscopes might decrease the number of attempts and time needed, especially among novices. We sought to compare videolaryngoscopes with direct laryngoscopes in simulated cardiopulmonary resuscitation scenarios. MATERIALS AND

methodsForty-four medical students were recruited to serve as novice users. Following brief, standardized training, students executed endotracheal intubation with the King Vision®, Macintosh and VividTrac® laryngoscopes, on a cardiopulmonary resuscitation trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction.

resultsIn the normal airway scenario, significantly shorter intubation times were achieved using the King Vision® than the Macintosh laryngoscope. In the difficult airway scenario, we found that the VividTrac® was superior to the King Vision® and Macintosh laryngoscopes in the laryngoscopy time. In both scenarios, we noted no difference in the first-attempt success rate, but the best view of the glottis and dental trauma, esophageal intubation and bougie use were more frequent with the Macintosh laryngoscope than with the videolaryngoscopes. The shortest tube insertion times were achieved using the King Vision® in both scenarios.

conclusionAll providers achieved successful intubation within three attempts, but we found no device superior in any of our scenarios regarding the first-attempt success rate. The King Vision® was superior to the Macintosh laryngoscope in the intubation time in the normal airway scenario and noninferior in the difficult airway scenario for novice users. We noted significantly less esophageal intubation using the videolaryngoscopes than using the Macintosh laryngoscope in both scenarios. Based on our results, the KingVision® might be recommended over the VividTrac® and Macintosh laryngoscopes for further evaluation.

Indexed as

AdultCardiopulmonary ResuscitationEducation, MedicalFemaleHumansIntubation, IntratrachealLaryngoscopesLaryngoscopyMaleReference StandardsRespiratory Physiological PhenomenaRespiratory SystemStudents, MedicalSurveys and QuestionnairesYoung Adult

Identifiers

PMID34793558
PMCPMC8601572
OpenAlexW3190096500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.