Novel microscope-based visual display and nasopharyngeal registration for auditory brainstem implantation: a feasibility study in an ex vivo model.

Milovan Regodić, Christian F Freyschlag, Johannes Kerschbaumer, Malik Galijašević, Romed Hörmann, Wolfgang Freysinger

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Electromagnetic Navigation in Cranial Neurosurgery.Advances and technical standards in neurosurgery · 2025
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Milovan RegodićDepartment of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria. milovan.regodic@student.i-med.ac.at.ORCID http://orcid.org/0000-0002-8244-9287
Christian F FreyschlagDepartment of Neurosurgery, Medical University of Innsbruck, Innsbruck, Austria.ORCID https://orcid.org/0000-0002-8228-8217
Johannes KerschbaumerDepartment of Neurosurgery, Medical University of Innsbruck, Innsbruck, Austria.ORCID https://orcid.org/0000-0002-9997-4336
Malik GalijaševićDepartment of Neuroradiology, Medical University of Innsbruck, Innsbruck, Austria.ORCID https://orcid.org/0000-0001-6577-0784
Romed HörmannDepartment of Anatomy, Histology and Embryology, Medical University of Vienna, Vienna, Austria.ORCID https://orcid.org/0000-0002-5542-077X
Wolfgang FreysingerDepartment of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria.ORCID https://orcid.org/0000-0002-2833-3224
Innsbruck Medical University · ATMedical University of Vienna · AT

Funding

Österreichische Forschungsfãrderungsgesellschaft (AT) 855783
6 · The paper itself

Abstract

purposeAn auditory brainstem implant (ABI) represents an alternative for patients with profound hearing loss who are constrained from receiving a cochlear implant. The positioning of the ABI electrode influences the patient's auditory capacity and, therefore, quality of life and is challenging even with available intraoperative electrophysiological monitoring. This work aims to provide and assess the feasibility of visual-spatial assistance for ABI positioning.

methodsThe pose of the forceps instrument that grasps the electrode was electromagnetically navigated and interactively projected in the eyepieces of a surgical microscope with respect to a target point. Intraoperative navigation was established with an experimental technique for automated nasopharyngeal patient registration. Two ABI procedures were completed in a human specimen head.

resultsAn intraoperative usability study demonstrated lower localization error when using the proposed visual display versus standard cross-sectional views. The postoperative evaluations of the preclinical study showed that the center of the electrode was misplaced to the planned position by 1.58 mm and 3.16 mm for the left and the right ear procedure, respectively.

conclusionThe results indicate the potential to enhance intraoperative feedback during ABI positioning with the presented system. Further improvements consider estimating the pose of the electrode itself to allow for better orientation during placement.

Indexed as

Auditory Brain Stem ImplantationCross-Sectional StudiesFeasibility StudiesHumansQuality of LifeTreatment OutcomeAuditory brainstem implantElectromagnetic trackingNeuronavigationRegistrationVisual guidance