Evidence map›Paper›PMID 34789168›Full record

ArticleClinical proteomics2021

Analytical validation of a multi-biomarker algorithmic test for prediction of progressive kidney function decline in patients with early-stage kidney disease.

Patricia Connolly, Sharon Stapleton, Gohar Mosoyan, Ilya Fligelman, Ya-Chen Tonar, Fergus Fleming, Michael J Donovan

Open access · goldAbstract read
In one paragraph

Article in Clinical proteomics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Patricia ConnollyRenalytix Inc., New York, NY, USA.ORCID http://orcid.org/0000-0002-9582-8630
Sharon StapletonRenalytix Inc., New York, NY, USA. sstapleton@renalytix.com.ORCID http://orcid.org/0000-0003-2048-3815
Gohar MosoyanRenalytix Inc., New York, NY, USA.ORCID http://orcid.org/0000-0003-2488-8510
Ilya FligelmanRenalytix Inc., New York, NY, USA.
Ya-Chen TonarRenalytix Inc., New York, NY, USA.
Fergus FlemingRenalytix Inc., New York, NY, USA.ORCID http://orcid.org/0000-0002-5276-6652
Michael J DonovanRenalytix Inc., New York, NY, USA.ORCID http://orcid.org/0000-0003-0772-598X
TiGenix (Spain) · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe KidneyIntelX™ test applies a machine learning algorithm that incorporates plasma biomarkers and clinical variables to produce a composite risk score to predict a progressive decline in kidney function in patients with type 2 diabetes (T2D) and early-stage chronic kidney disease (CKD). The following studies describe the analytical validation of the KidneyIntelX assay including impact of observed methodologic variability on the composite risk score.

methodsAnalytical performance studies of sensitivity, precision, and linearity were performed on three biomarkers assayed in multiplexed format: kidney injury molecule-1 (KIM-1), soluble tumor necrosis factor receptor-1 (sTNFR-1) and soluble tumor necrosis factor receptor-2 (sTNFR-2) based on Clinical Laboratory Standards Institute (CLSI) guidelines. Analytical variability across twenty (20) experiments across multiple days, operators, and reagent lots was assessed to examine the impact on the reproducibility of the composite risk score. Analysis of cross-reactivity and interfering substances was also performed.

resultsAssays for KIM-1, sTNFR-1 and sTNFR-2 demonstrated acceptable sensitivity. Mean within-laboratory imprecision coefficient of variation (CV) was established as less than 9% across all assays in a multi-lot study. The linear range of the assays was determined as 12-5807 pg/mL, 969-23,806 pg/mL and 4256-68,087 pg/mL for KIM-1, sTNFR-1 and sTNFR-2, respectively. The average risk score CV% was less than 5%, with 98% concordance observed for assignment of risk categories. Cross-reactivity between critical assay components in a multiplexed format did not exceed 1.1%.

conclusionsThe set of analytical validation studies demonstrated robust analytical performance across all three biomarkers contributing to the KidneyIntelX risk score, meeting or exceeding specifications established during characterization studies. Notably, reproducibility of the composite risk score demonstrated that expected analytical laboratory variation did not impact the assigned risk category, and therefore, the clinical validity of the reported results.

Indexed as

Analytical validationDiabetic kidney diseaseKidneyIntelXKIM-1sTNFR-1sTNFR-2

Identifiers

PMID34789168
PMCPMC8597271
OpenAlexW3212284440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.