Evidence map›Paper›PMID 34784459›Full record

ArticleAnesthesia and pain medicine2022

Verification of the performance of the Bispectral Index as a hypnotic depth indicator during dexmedetomidine sedation.

Seunghee Ki, Dongeon Lee, Wonjin Lee, Kwangrae Cho, Yongjae Han, Jeonghan Lee

Open access · goldAbstract read
In one paragraph

Article in Anesthesia and pain medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Seunghee KiDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Dongeon LeeDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Wonjin LeeDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Kwangrae ChoDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Yongjae HanDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Jeonghan LeeDepartment of Anesthesiology and Pain Medicine, Inje University College of Medicine, Busan, Korea.
Inje University · KR

Funding

Inje University Busan Paik Hospital
6 · The paper itself

Abstract

backgroundDifferences in the effects of propofol and dexmedetomidine sedation on electroencephalogram patterns have been reported previously. However, the reliability of the Bispectral Index (BIS) value for assessing the sedation caused by dexmedetomidine remains debatable. The purpose of this study is to evaluate the correlation between the BIS value and the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scale in patients sedated with dexmedetomidine.

methodsForty-two patients (age range, 20-80 years) who were scheduled for elective surgery under spinal anesthesia were enrolled in this study. Spinal anesthesia was performed using 0.5% bupivacaine, which was followed by dexmedetomidine infusion (loading dose, 0.5-1 μg/kg for 10 min; maintenance dose, 0.3-0.6 μg/kg/h). The MOAA/S score was used to evaluate the level of sedation, and the Vital Recorder program was used to collect data (vital signs and BIS values).

resultsA total of 215082 MOAA/S scores and BIS data pairs were analyzed. The baseline variability of the BIS value was 7.024%, and the decrease in the BIS value was associated with a decrease in the MOAA/S score. The correlation coefficient and prediction probability between the two measurements were 0.566 (P < 0.0001) and 0.636, respectively. The mean ± standard deviation values of the BIS were 87.22 ± 7.06, 75.85 ± 9.81, and 68.29 ± 12.65 when the MOAA/S scores were 5, 3, and 1, respectively. Furthermore, the cut-off BIS values in the receiver operating characteristic analysis at MOAA/S scores of 5, 3, and 1 were 82, 79, and 73, respectively.

conclusionThe BIS values were significantly correlated with the MOAA/S scores. Thus, the BIS along with the clinical sedation scale might prove useful in assessing the hypnotic depth of a patient during sedation with dexmedetomidine.

Indexed as

Anesthesia, spinalConsciousness monitorsDexmedetomidineHypnotics and sedatives

Identifiers

PMID34784459
PMCPMC8841253
OpenAlexW3199226938

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.