ArticleJournal of applied clinical medical physics2021

Characterization of size-specific effects during dual-energy CT material decomposition of non-iodine materials.

Jessica Miller, Lianna DiMaso, Jessie Huang-Vredevoogd, Jainil Shah, Michael Lawless

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jessica MillerDepartment of Human Oncology, University of Wisconsin, Madison, Wisconsin, USA.
Lianna DiMasoDepartment of Human Oncology, University of Wisconsin, Madison, Wisconsin, USA.
Jessie Huang-VredevoogdDepartment of Human Oncology, University of Wisconsin, Madison, Wisconsin, USA.
Jainil ShahSiemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA.
Michael LawlessDepartment of Human Oncology, University of Wisconsin, Madison, Wisconsin, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe dual-energy CT (DECT) LiverVNC application class in the Siemens Syngo.via software has been used to perform non-iodine material decompositions. However, the LiverVNC application is designed with an optional size-specific calibration based on iodine measurements. This work investigates the effects of this iodine-based size-specific calibration on non-iodine material decomposition and benchmarks alternative methods for size-specific calibrations.

methodsCalcium quantification was performed with split-filter and sequential-scanning DECT techniques on the Siemens SOMATOM Definition Edge CT scanner. Images were acquired of the Gammex MECT abdomen and head phantom containing calcium inserts with concentrations ranging from 50-300 mgCa/ml. Several workflows were explored investigating the effects of size-specific dual-energy ratios (DERs) and the beam hardening correction (BHC) function in the LiverVNC application. Effects of image noise were also investigated by varying CTDI

resultsWith the default BHC activated, Syngo.via underestimated the calcium concentrations in the abdomen for sequential-scanning acquisitions, leaving residual calcium in the virtual non-contrast images and underestimating calcium in the enhancement images for all DERs. Activation of the BHC with split-filter images resulted in a calcium over- or underestimation depending on the DER. With the BHC inactivated, the use of a single DER led to an under- or overestimate of calcium concentration depending on phantom size and DECT modality. Optimal results were found with BHC inactivated using size-specific DERs. CTDI

conclusionWhen performing non-iodine material decomposition in the LiverVNC application class, it is important to understand the implications of the BHC function and to account for patient size appropriately. The BHC in the LiverVNC application is specific to iodine and leads to inaccurate quantification of other materials. The inaccuracies can be overcome by deactivating the BHC function and using size-specific DERs, which provided the most accurate calcium quantification.

Indexed as

IodineCalibrationHumansPhantoms, ImagingTomography Scanners, X-Ray ComputedTomography, X-Ray ComputedIodineCT simulationdual-energy CT

Identifiers

PMID34783427
PMCPMC8664138

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.