ArticleEye and vision (London, England)2021
Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results.
Article in Eye and vision (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.
- Efficacy analysis of microinvasive glaucoma surgery alone or in combination with phacoemulsification in patients with normal tension glaucoma: a systematic review and meta-analysis.BMC ophthalmology · 2025Pooled it
- Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis.BMJ open ophthalmology · 2024Pooled it
- Progress in Glaucoma Management in the Era of Value-Based Healthcare.Journal of clinical medicine · 2025Article
- Cataract surgery with and without trabecular micro-bypass stent in primary angle-closure glaucoma: a multi-centre cohort study.Eye (London, England) · 2025Article
- Midterm Outcomes of a Bangladeshi Modification of Bent Ab Interno Needle Goniectomy (B-BANG): Single-Surgeon Pilot Study.BioMed research international · 2025Article
- From first generation to the next: evolution and research trends in iStent technology.Frontiers in medicine · 2025Review
- Ten-Year Effectiveness and Safety of Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in Patients with Glaucoma or Ocular Hypertension.Ophthalmology and therapy · 2024Article
- 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage.Advances in therapy · 2024Article
- Consistency in Standalone Canaloplasty Outcomes Using the iTrack Microcatheter.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Comparison of Phacoemulsification Alone and With Trabecular Microbypass Stent in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma: An 18-Month Outcome Study.Journal of ophthalmology · 2024Article
- Five-Year Outcomes of Single Trabecular Microbypass Stent (iStentOphthalmology and therapy · 2023Article
- New Devices in Glaucoma.Ophthalmology and therapy · 2023Review
- Efficacy and Safety of Pairing iStent Inject Trabecular Micro-Bypass and iAccess Precision Blade Goniotomy in Patients with Open-Angle Glaucoma.Ophthalmology and therapy · 2023Article
- The effectiveness and safety of one-stage iStent-based micro-invasive glaucoma surgery-A retrospective study.Frontiers in medicine · 2023Article
- Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma.Clinical ophthalmology (Auckland, N.Z.) · 2023Review
- Ethnopharmacology, Biological Evaluation, and Chemical Composition ofAdvances in pharmacological and pharmaceutical sciences · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up.
methodsThis longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events.
resultsA total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease.
conclusionsImplantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.