ArticleInternational journal of radiation oncology, biology, physics2022
The Value of On-Site Proton Audits.
Article in International journal of radiation oncology, biology, physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Trends and Challenges: A 15-Year Review of Imaging and Radiation Oncology Core Anthropomorphic Phantom Audits for Proton Therapy.International journal of particle therapy · 2026Article
- Technical note: Radiological clinical equivalence for phantom materials in carbon ion therapy.Medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeThis study aimed to highlight the value and key findings of on-site proton audits. METHODS AND MATERIALS: The authors performed 38 on-site measurement-based peer reviews of proton centers participating in National Cancer Institute-funded clinical trials. The reviews covered beam calibration, lateral and depth measurements, mechanical checks, treatment planning and clinical practice, and quality assurance (QA) practices. Program deficiencies were noted, and recommendations were made about ways institutions could improve their practices.
resultsInstitutions received an average of 3 (range, 1-8) recommendations for practice improvements. The number of deficiencies did not decrease over time, highlighting the continued need for this type of peer review. The most common deficiencies were for Task Group-recommended QA compliance (97% of centers), computed tomography number (CTN) to relative linear stopping power conversion (59%), and QA procedures (53%). In addition, 32% of institutions assessed failed at least 1 lateral beam profile measurement (<90% of pixels passing 3% [global]/3 mm; 10% threshold), despite passing internal QA measurements. These failures occurred for several different plan configurations (large, small, shallow, and deep targets) and at different depths in the beam path (proximal to target, central, and distal). CTN to relative linear stopping power conversion curves showed deviations at low, mid, and high CTNs and highlighted areas of inconsistency between proton centers, with many centers falling outside of 2 sigma of the mean curve of their peers. All deficiencies from the peer review were discussed with the institutions, and many implemented dosimetric treatment planning and practice changes to improve the accuracy of their system and consistency with other institutions.
conclusionsThis peer review program has been integral in confirming and promoting consistency and best practice across proton centers for clinical trials, minimizing deviations for outcomes data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.