ArticleApplied bionics and biomechanics2021
Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models.
Article in Applied bionics and biomechanics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The assessment of the distribution of contact pressure on the meniscus is important in the elucidation of kinematics, etiology of joint diseases, and establishment of treatment methods. Compared with sensors widely used in recent years, pressure-sensitive conductive rubber sensors are easy to mold, flexible, durable, and resistant to shearing forces. This study is aimed at developing a rubber sensor for meniscal research and evaluating the pressure distribution after meniscal injury using porcine models. After confirming the reliability of the rubber sensor, contact pressure was obtained from the rubber sensor using the medial meniscus and femur of the porcine knee. Three test conditions of intact meniscus, radial tear, and meniscectomy were prepared, and a compressive load of 100 N was applied. After confirming the high reliability of the rubber sensor, the intact meniscus had the most uniform pressure distribution map, while the pressure in the meniscectomy model was concentrated in the resection region. The high-pressure region was significantly smaller in the intact group than in the radial tear models after 80 and 100 N (
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.