Reliability and efficiency of corneal thickness measurements using sterile donor tomography in the eye bank.

Loïc Hamon, Adrien Quintin, Stephanie Mäurer, Isabel Weinstein, Achim Langenbucher, Berthold Seitz, Loay Daas

Open access · hybridAbstract read
In one paragraph

Article in Cell and tissue banking, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. In situ donor keratometry in deceased patients as a novel screening technique for eye banking.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Loïc HamonDepartment of Ophthalmology, Saarland University Medical Center (UKS), Kirrberger Straße 100, Bldg. 22, 66421, Homburg/Saar, Germany. loic.hamon@uks.eu.ORCID http://orcid.org/0000-0002-3284-9901
Adrien QuintinDepartment of Ophthalmology, Saarland University Medical Center (UKS), Kirrberger Straße 100, Bldg. 22, 66421, Homburg/Saar, Germany.ORCID http://orcid.org/0000-0003-0452-3039
Stephanie MäurerInstitute of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany.
Isabel WeinsteinDepartment of Ophthalmology, Saarland University Medical Center (UKS), Kirrberger Straße 100, Bldg. 22, 66421, Homburg/Saar, Germany.ORCID http://orcid.org/0000-0002-1590-4868
Achim LangenbucherInstitute of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany.ORCID http://orcid.org/0000-0001-9175-6177
Berthold SeitzDepartment of Ophthalmology, Saarland University Medical Center (UKS), Kirrberger Straße 100, Bldg. 22, 66421, Homburg/Saar, Germany.ORCID http://orcid.org/0000-0001-9701-8204
Loay DaasDepartment of Ophthalmology, Saarland University Medical Center (UKS), Kirrberger Straße 100, Bldg. 22, 66421, Homburg/Saar, Germany.ORCID http://orcid.org/0000-0001-8076-3179
Saarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To evaluate the reliability and efficiency of sterile pachymetric measurements of donor corneas based on tomographic data using two different methods: a "manual" and a "(semi-)automated" method. Twenty-five (25) donor corneas (50%) stored in MI and 25 (50%) in MII were imaged 5 times consecutively using an anterior segment OCT (AS-OCT). The central corneal thickness (CCT) was measured both with the manual measurement tool of the AS-OCT (= CCTm) and with a MATLAB self-programmed software allowing (semi-)automated analysis (= CCTa). We analyzed the reliability of CCTm and CCTa using Cronbach´s alpha (α) and Wilcoxon signed-Rank Test. Concerning CCTm, 68 measurements (54.4%) in MI and 46 (36.8%) in MII presented distortions in the imaged 3D-volumes and were discarded. Concerning CCTa, 5 (4%) in MI and 1 (0.8%) in MII were not analyzable. The mean (± SD) CCTm was 1129 ± 6.8 in MI and 820 ± 5.1 µm in MII. The mean CCTa was 1149 ± 2.7 and 811 ± 2.4 µm, respectively. Both methods showed a high reliability with a Cronbach´s α for CCTm of 1.0 (MI/MII) and for CCTa of 0.99 (MI) and 1.0 (MII). Nevertheless, the mean SD of the 5 measurements was significantly higher for CCTm compared to CCTa in MI (p = 0.03), but not in MII (p = 0.92). Sterile donor tomography proves to be highly reliable for assessment of CCT with both methods. However, due to frequent distortions regarding the manual method, the (semi-)automated method is more efficient and should be preferred.

Indexed as

Eye BanksTomography, Optical CoherenceCorneaCorneal PachymetryReproducibility of ResultsDonor corneaEfficiencyEye bankOptical coherence tomographyOrgan cultureReliability

Identifiers

PMID34773544
PMCPMC9675654
OpenAlexW3212455646

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.