Evidence map›Paper›PMID 34773485›Full record

ArticleSkeletal radiology2022

Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study.

Sebastian Simon, Gilbert M Schwarz, Alexander Aichmair, Bernhard J H Frank, Allan Hummer, Matthew D DiFranco, Martin Dominkus, Jochen G Hofstaetter

Abstract read
PubMed Publisher
In one paragraph

Article in Skeletal radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sebastian SimonMichael-Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria.
Gilbert M SchwarzMichael-Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria.
Alexander AichmairMichael-Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria.
Bernhard J H FrankMichael-Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria.
Allan HummerImage Biopsy Lab GmbH, Zehetnergasse 6/2/2, 1140, Vienna, Austria.
Matthew D DiFrancoImage Biopsy Lab GmbH, Zehetnergasse 6/2/2, 1140, Vienna, Austria.
Martin DominkusII. Department of Orthopaedic Surgery, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria.
Jochen G HofstaetterMichael-Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130, Vienna, Austria. researchlab@oss.at.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAccurate assessment of knee alignment and leg length discrepancy is currently measured manually from standing long-leg radiographs (LLR), a process that is both time consuming and poorly reproducible. The aim was to assess the performance of a commercial available AI software by comparing its outputs with manually performed measurements. MATERIALS AND

methodsThe AI was trained on over 15,000 radiographs to measure various clinical angles and lengths from LLRs. We performed a retrospective single-center analysis on 295 LLRs obtained between 2015 and 2020 from male and female patients over 18 years. AI and expert measurements were performed independently. Kellgren-Lawrence score and reading time were assessed. All measurements were compared and non-inferiority, mean-absolute-deviation (sMAD), and intra-class-correlation (ICC) were calculated.

resultsA total of 295 LLRs from 284 patients (mean age, 65 years (18; 90); 97 (34.2%) men) were analyzed. The AI model produces outputs on 98.0% of the LLRs. Manually annotations were considered as 100% accurate. For each measurement, its divergence was calculated, resulting in an overall accuracy of 89.2% when comparing the AI outputs to the manually measured. AI vs. mean observer revealed an sMAD between 0.39 and 2.19° for angles and 1.45-5.00 mm for lengths. AI showed good reliability in all lengths and angles (ICC ≥ 0.87). Non-inferiority comparing AI to the mean observer revealed an equivalence-index (γ) between 0.54 and 3.03° for angles and - 0.70-1.95 mm for lengths. On average, AI was 130 s faster than clinicians.

conclusionAutomated measurements of knee alignment and length measurements produced with an AI tool result in reproducible, accurate measures with a time savings compared to manually acquired measurements.

Indexed as

Deep LearningAgedCross-Sectional StudiesFemaleHumansLower ExtremityMaleReproducibility of ResultsRetrospective StudiesArtificial intelligenceBig dataKnee alignmentLong-leg radiographsStandardization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked