Evidence map›Paper›PMID 34772847›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2022

Characterization and Development of Universal Ventricular Assist Device: Computational Fluid Dynamics Analysis of Advanced Design.

Mark S Goodin, Michael S Showalter, David J Horvath, Barry D Kuban, Christine R Flick, Anthony R Polakowski, Kiyotaka Fukamachi, Jamshid H Karimov

Open access · greenAbstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 60% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Mark S GoodinSimuTech Group, Hudson, Ohio.ORCID 0000-0002-4095-5720
Michael S ShowalterSimuTech Group, Huntsville, Alabama.
David J HorvathR1 Engineering LLC, Euclid.ORCID 0000-0002-5469-2490
Barry D KubanDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland and.ORCID 0000-0002-8388-3050
Christine R FlickDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland and.
Anthony R PolakowskiDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland and.
Kiyotaka FukamachiDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland and.ORCID 0000-0002-4852-8416
Jamshid H KarimovDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland and.ORCID 0000-0002-0167-0415
Cleveland Clinic Lerner College of Medicine · USCase Western Reserve University · USSimuTech Group (United States) · US

Funding

Advanced Ventricular Assist Device with Pulse Augmentation and Automatic Regurgitant Flow ShutoffR21HL133871 · NHLBI · CLEVELAND CLINIC LERNER COM-CWRU · PI FUKAMACHI, KIYOTAKA · 2016 to 2017
$434k
NHLBI NIH HHS R21 HL133871
6 · The paper itself

Abstract

We are developing a universal, advanced ventricular assist device (AVAD) with automatic pressure regulation suitable for both left and right ventricular support. The primary goal of this computational fluid dynamics (CFD) study was to analyze the biventricular performance of the AVAD across its wide range of operating conditions. An AVAD CFD model was created and validated using in vitro hydraulic performance measurements taken over conditions spanning both left ventricular assist device (LVAD) and right ventricular assist device (RVAD) operation. Static pressure taps, placed throughout the pump, were used to validate the CFD results. The CFD model was then used to assess the change in hydraulic performance with varying rotor axial positions and identify potential design improvements. The hydraulic performance was simulated and measured at rotor speeds from 2,300 to 3,600 revolutions/min and flow rates from 2.0 to 8.0 L/min. The CFD-predicted hydraulic pressure rise agreed well with the in vitro measured data, within 6.5% at 2300 rpm and within 3.5% for the higher rotor speeds. The CFD successfully predicted wall static pressures, matching experimental values within 7%. High degree of similarity and circumferential uniformity in the pump's flow fields were observed over the pump operation as an LVAD and an RVAD. A secondary impeller axial clearance reduction resulted in a 10% decrease in peak flow residence time and lower static pressures on the secondary impeller. These lower static pressures suggest a reduction in the upwards rotor forces from the secondary impeller and a desired increase in the pressure sensitivity of the pump. The CFD analyses supported the feasibility of the proposed AVAD's use as an LVAD or an RVAD, over a wide range of operating conditions. The CFD results demonstrated the operability of the pump in providing the desired circumferential flow similarity over the intended range of flow/speed conditions and the intended functionality of the AVAD's automated pressure regulation.

Indexed as

Heart-Assist DevicesEquipment DesignHydrodynamicsModels, Cardiovascular

Identifiers

PMID34772847
PMCPMC9085974
OpenAlexW3213349869

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.