Trial reportThe British journal of ophthalmology2023
Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial.
Trial report in The British journal of ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03756662 (A Prospective, Open-label, Single Arm, Multicenter Clinical Investigation to Assess the Safety and Performance of the ARGOS-SC Suprachoroidal Pressure Sensor System in Patients With Glaucoma Undergoing Non-penetrating Glaucoma Surgery), which is not on this map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Prospective, Open-label, Single Arm, Multicenter Clinical Investigation to Assess the Safety and Performance of the ARGOS-SC Suprachoroidal Pressure Sensor System in Patients With Glaucoma Undergoing Non-penetrating Glaucoma Surgery
Who cites it
14 citing papers in PubMed, 21 citations in OpenAlex.
- Home monitoring devices for glaucoma.Indian journal of ophthalmology · 2026Review
- [Telemetric self-monitoring of intraocular pressure: from vision to reality? : Insights from the EyeMate-SC sensor].Die Ophthalmologie · 2026Review
- What Do Infrequent Goldmann Applanation Tonometry Measurements Reveal About Intraocular Pressure Profiles After Nonpenetrating Glaucoma Surgery?Translational vision science & technology · 2026Article
- Machine Learning-Based Prediction of Long-Term Intraocular Pressure Fluctuations in Open-Angle Glaucoma.Ophthalmology science · 2026Article
- Short-term refractive and corneal astigmatism after canal-based microinvasive glaucoma surgery.PloS one · 2026Observational
- Current and Emerging Technologies for Continuous Intraocular Pressure Monitoring in the Control of Glaucoma Progression: A Scoping Review.Journal of clinical medicine · 2025Review
- Validation of the EYEMATE-SC Suprachoroidal Pressure Transducer for Telemetric Measurement of Intraocular Pressure in Normal Ex Vivo Canine and Equine Globes-Preliminary Results.Veterinary ophthalmology · 2025Article
- Long-Term in vivo Positional Stability of a Suprachoroidal Telemetric Intraocular Pressure Sensor Implant.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- The relationship between intraocular pressure and glaucoma: An evolving concept.Progress in retinal and eye research · 2024Review
- Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma.Science advances · 2024Article
- The Benefit of Nocturnal IOP Reduction in Glaucoma, Including Normal Tension Glaucoma.Clinical ophthalmology (Auckland, N.Z.) · 2024Review
- Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review.Micromachines · 2023Review
- Advances in Canaloplasty-Modified Techniques Yield Strong Pressure Reduction with Low Risk Profile.Journal of clinical medicine · 2023Review
- [Modifications of canaloplasty : Strong pressure-lowering effect with a low risk profile].Die Ophthalmologie · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimTo investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS).
methodsProspective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor's safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tonometry (GAT).
resultsThe eyes underwent canaloplasty (n=15) or deep sclerectomy (n=9) and achieved successful implantation of the sensor. No device migration, dislocation or serious device-related complications occurred. A total of 367 comparisons were included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 1.31 mm Hg (lower limit of agreement (LoA) 7.55 mm Hg; upper LoA -4.92 mm Hg). The maximum difference of 2.5 mm Hg ±3.96 (LoA 0.30-2.29) was reached on day 10 and continuously improved to an agreement of -0.15 mm Hg ±2.28 (LoA -1.24 to 0.89) after 6 months. Accordingly, the percentage of eyes within an IOP difference of ±5 mm Hg improved from 78% (day 3) to 100% (6 months).
conclusionsAfter 6 months, the EYEMATE-SC sensor was safe and well tolerated, and allowed continual IOP monitoring. TRIAL REGISTRATION NUMBER: NCT03756662.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.