Evidence map›Paper›PMID 34770723›Full record

ArticleSensors (Basel, Switzerland)2021

Non-Singleton Type-3 Fuzzy Approach for Flowmeter Fault Detection: Experimental Study in a Gas Industry.

Jing-He Wang, Jafar Tavoosi, Ardashir Mohammadzadeh, Saleh Mobayen, Jihad H Asad, Wudhichai Assawinchaichote, Mai The Vu, Paweł Skruch

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jing-He WangSchool of Economics and Finance, Huaqiao University, Quanzhou 362021, China.
Jafar TavoosiDepartment of Electrical Engineering, Ilam University, Ilam 69315516, Iran.ORCID 0000-0003-1209-1811
Ardashir MohammadzadehElectrical Engineering Department, University of Bonab, Bonab 5551395133, Iran.ORCID 0000-0001-5173-4563
Saleh MobayenFuture Technology Research Center, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.ORCID 0000-0002-5676-1875
Jihad H AsadDepartment of Physics, Faculty of Applied Sciences, Palestine Technical University, Tulkarm P.O. Box 7, Palestine.
Wudhichai AssawinchaichoteDepartment of Electronic and Telecommunication Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand.ORCID 0000-0003-1333-5646
Mai The VuSchool of Intelligent Mechatronics Engineering, Sejong University, Seoul 05006, Korea.ORCID 0000-0003-1645-0957
Paweł SkruchDepartment of Automatic Control and Robotics, AGH University of Science and Technology, 30-059 Kraków, Poland.ORCID 0000-0002-8290-8375

Funding

Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering of the AGH University of Science and Technology, Cracow, Poland 16.16.120.773Ministry of Science and Technology (MOST), Taiwan 110-2222-E-224-001
6 · The paper itself

Abstract

The main contribution of this paper is to develop a new flowmeter fault detection approach based on optimized non-singleton type-3 (NT3) fuzzy logic systems (FLSs). The introduced method is implemented on an experimental gas industry plant. The system is modeled by NT3FLSs, and the faults are detected by comparison of measured end estimated signals. In this scheme, the detecting performance depends on the estimation and modeling performance. The suggested NT3FLS is used because of the existence of a high level of measurement errors and uncertainties in this problem. The designed NT3FLS with uncertain footprint-of-uncertainty (FOU), fuzzy secondary memberships and adaptive non-singleton fuzzification results in a powerful tool for modeling signals immersed in noise and error. The level of non-singleton fuzzification and membership parameters are tuned by maximum correntropy (MC) unscented Kalman filter (KF), and the rule parameters are learned by correntropy KF (CKF) with fuzzy kernel size. The suggested learning algorithms can handle the non-Gaussian noises that are common in industrial applications. The various types of flowmeters are investigated, and the effect of common faults are examined. It is shown that the suggested approach can detect the various faults with good accuracy in comparison with conventional approaches.

Indexed as

FlowmetersAlgorithmsFuzzy LogicIndustrycorrentropy Kalman filterfault detectionlearning algorithmnon-Gaussian noisetype-3 fuzzy logic

Identifiers

PMID34770723
PMCPMC8587827

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.