Evidence map›Paper›PMID 34770677›Full record

ArticleSensors (Basel, Switzerland)2021

Multi-Focus Image Fusion Using Focal Area Extraction in a Large Quantity of Microscopic Images.

Jiyoung Lee, Seunghyun Jang, Jungbin Lee, Taehan Kim, Seonghan Kim, Jongbum Seo, Ki Hean Kim, Sejung Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jiyoung LeeDepartment of Biomedical Engineering, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Korea.
Seunghyun JangDepartment of Biomedical Engineering, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Korea.ORCID 0000-0003-4703-7006
Jungbin LeeDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.ORCID 0000-0001-6914-5310
Taehan KimDepartment of Biomedical Engineering, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Korea.ORCID 0000-0002-6963-6483
Seonghan KimDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.
Jongbum SeoDepartment of Biomedical Engineering, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Korea.
Ki Hean KimDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.
Sejung YangDepartment of Biomedical Engineering, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Korea.ORCID 0000-0002-5841-851X

Funding

Basic Science Research Program 2019R1F1A1058971Institute of Information & Communications Technology Planning & Evaluation 2020-0-00989
6 · The paper itself

Abstract

The non-invasive examination of conjunctival goblet cells using a microscope is a novel procedure for the diagnosis of ocular surface diseases. However, it is difficult to generate an all-in-focus image due to the curvature of the eyes and the limited focal depth of the microscope. The microscope acquires multiple images with the axial translation of focus, and the image stack must be processed. Thus, we propose a multi-focus image fusion method to generate an all-in-focus image from multiple microscopic images. First, a bandpass filter is applied to the source images and the focus areas are extracted using Laplacian transformation and thresholding with a morphological operation. Next, a self-adjusting guided filter is applied for the natural connections between local focus images. A window-size-updating method is adopted in the guided filter to reduce the number of parameters. This paper presents a novel algorithm that can operate for a large quantity of images (10 or more) and obtain an all-in-focus image. To quantitatively evaluate the proposed method, two different types of evaluation metrics are used: "full-reference" and "no-reference". The experimental results demonstrate that this algorithm is robust to noise and capable of preserving local focus information through focal area extraction. Additionally, the proposed method outperforms state-of-the-art approaches in terms of both visual effects and image quality assessments.

Indexed as

AlgorithmsImage Processing, Computer-AssistedMicroscopyall-in-focusdepth of fieldimage fusionmicroscopy

Identifiers

PMID34770677
PMCPMC8586970

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.