Evidence map›Paper›PMID 34770643›Full record

Observational studySensors (Basel, Switzerland)2021

A Measurement of 'Walking-the-Wall' Dynamics: An Observational Study Using Accelerometry and Sensors to Quantify Risk Associated with Vertical Wall Impact Attenuation in Trampoline Parks.

Imam Hossain, Shilei Zhou, Karlos Ishac, Edward Lind, Lisa Sharwood, David Eager

Abstract readObservational Study
In one paragraph

Observational study in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Imam HossainFaculty of Engineering and Information Technology, University of Technology Sydney, Sydney 2007, Australia.ORCID 0000-0002-1246-3454
Shilei ZhouFaculty of Engineering and Information Technology, University of Technology Sydney, Sydney 2007, Australia.ORCID 0000-0001-5070-141X
Karlos IshacFaculty of Engineering and Information Technology, University of Technology Sydney, Sydney 2007, Australia.ORCID 0000-0001-6215-3297
Edward LindFaculty of Engineering and Information Technology, University of Technology Sydney, Sydney 2007, Australia.
Lisa SharwoodFaculty of Medicine and Health, University of Sydney, Sydney 2006, Australia.ORCID 0000-0001-8977-6144
David EagerFaculty of Engineering and Information Technology, University of Technology Sydney, Sydney 2007, Australia.ORCID 0000-0003-1926-7867

Funding

University of Technology Sydney Not applicable
6 · The paper itself

Abstract

This study illustrates the application of a tri-axial accelerometer and gyroscope sensor device on a trampolinist performing the walking-the-wall manoeuvre on a high-performance trampoline to determine the performer dynamic conditions. This research found that rigid vertical walls would allow the trampolinist to obtain greater control and retain spatial awareness at greater levels than what is achievable on non-rigid vertical walls. With a non-rigid padded wall, the reaction force from the wall can be considered a variable force that is not constrained, and would not always provide the feedback that the trampolinist needs to maintain the balance with each climb up the wall and fall from height. This research postulates that unattenuated vertical walls are safer than attenuated vertical walls for walking-the-wall manoeuvres within trampoline park facilities. This is because non-rigid walls would provide higher g-force reaction feedback from the wall, which would reduce the trampolinist's control and stability. This was verified by measuring g-force on a horizontal rigid surface versus a non-rigid surface, where the g-force feedback was 27% higher for the non-rigid surface. Control and stability are both critical while performing the complex walking-the-wall manoeuvre. The trampolinist experienced a very high peak g-force, with a maximum g-force of approximately 11.5 g at the bottom of the jump cycle. It was concluded that applying impact attenuation padding to vertical walls used for walking-the-wall and similar activities would increase the likelihood of injury; therefore, padding of these vertical surfaces is not recommended.

Indexed as

AccelerometryWalkingHumansaccelerometerinjury riskparkourstabilitytaekwondotrampoline manoeuvretrampoline parkstrampoline safetytrampolinist

Identifiers

PMID34770643
PMCPMC8587968

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.