Evidence map›Paper›PMID 34770640›Full record

ArticleSensors (Basel, Switzerland)2021

UV Hyperspectral Imaging as Process Analytical Tool for the Characterization of Oxide Layers and Copper States on Direct Bonded Copper.

Mohammad Al Ktash, Mona Stefanakis, Tim Englert, Maryam S L Drechsel, Jan Stiedl, Simon Green, Timo Jacob, Barbara Boldrini, Edwin Ostertag, Karsten Rebner and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Mohammad Al KtashProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.ORCID 0000-0002-6713-5669
Mona StefanakisProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.ORCID 0000-0002-9459-0640
Tim EnglertRobert Bosch GmbH, Automotive Electronics, Postfach 1342, 72703 Reutlingen, Germany.ORCID 0000-0001-8622-917X
Maryam S L DrechselProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.
Jan StiedlRobert Bosch GmbH, Automotive Electronics, Postfach 1342, 72703 Reutlingen, Germany.
Simon GreenRobert Bosch GmbH, Automotive Electronics, Postfach 1342, 72703 Reutlingen, Germany.
Timo JacobInstitute of Electrochemistry, Ulm University, Albert-Einstein-Allee 47, 89081 Ulm, Germany.ORCID 0000-0001-7777-2306
Barbara BoldriniProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.
Edwin OstertagProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.ORCID 0000-0003-0492-0544
Karsten RebnerProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.ORCID 0000-0002-3577-2903
Marc BrechtProcess Analysis and Technology PA & T, Reutlingen University, Alteburgstraße 150, 72762 Reutlingen, Germany.ORCID 0000-0001-5537-1448

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hyperspectral imaging and reflectance spectroscopy in the range from 200-380 nm were used to rapidly detect and characterize copper oxidation states and their layer thicknesses on direct bonded copper in a non-destructive way. Single-point UV reflectance spectroscopy, as a well-established method, was utilized to compare the quality of the hyperspectral imaging results. For the laterally resolved measurements of the copper surfaces an UV hyperspectral imaging setup based on a pushbroom imager was used. Six different types of direct bonded copper were studied. Each type had a different oxide layer thickness and was analyzed by depth profiling using X-ray photoelectron spectroscopy. In total, 28 samples were measured to develop multivariate models to characterize and predict the oxide layer thicknesses. The principal component analysis models (PCA) enabled a general differentiation between the sample types on the first two PCs with 100.0% and 96% explained variance for UV spectroscopy and hyperspectral imaging, respectively. Partial least squares regression (PLS-R) models showed reliable performance with

Indexed as

CopperHyperspectral ImagingLeast-Squares AnalysisOxidesPrincipal Component AnalysisCopperOxidescopper oxide layer thicknessdirect bonded copperhyperspectral imagingpartial least squares regressionprincipal component analysispushbroomUV spectroscopy

Identifiers

PMID34770640
PMCPMC8588143

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.