Evidence map›Paper›PMID 34770534›Full record

ArticleSensors (Basel, Switzerland)2021

Efficient Strike Artifact Reduction Based on 3D-Morphological Structure Operators from Filtered Back-Projection PET Images.

Chun-Yi Chiu, Yung-Hui Huang, Wei-Chang Du, Chi-Yuan Wang, Huei-Yong Chen, Yun-Shiuan Shiu, Nan-Han Lu, Tai-Been Chen

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 79% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Chun-Yi ChiuDepartment of Radiology, Kaohsiung Veterans General Hospital, No. 386, Dazhong 1st Rd., Zuoying District, Kaohsiung City 81362, Taiwan.
Yung-Hui HuangDepartment of Medical Imaging and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.ORCID 0000-0003-3808-9998
Wei-Chang DuDepartment of Information Engineering, I-Shou University, No. 1, Sec. 1, Xuecheng Rd., Dashu District, Kaohsiung City 84001, Taiwan.
Chi-Yuan WangDepartment of Medical Imaging and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.
Huei-Yong ChenDepartment of Nuclear Medicine, E-DA Hospital, No. 1, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.
Yun-Shiuan ShiuDepartment of Nuclear Medicine, E-DA Hospital, No. 1, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.
Nan-Han LuDepartment of Medical Imaging and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.
Tai-Been ChenDepartment of Medical Imaging and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao District, Kaohsiung City 82445, Taiwan.ORCID 0000-0002-3348-4422
I-Shou University · TWE-Da Hospital · TWKaohsiung Veterans General Hospital · TWTajen University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Positron emission tomography (PET) can provide functional images and identify abnormal metabolic regions of the whole-body to effectively detect tumor presence and distribution. The filtered back-projection (FBP) algorithm is one of the most common images reconstruction methods. However, it will generate strike artifacts on the reconstructed image and affect the clinical diagnosis of lesions. Past studies have shown reduction in strike artifacts and improvement in quality of images by two-dimensional morphological structure operators (2D-MSO). The morphological structure method merely processes the noise distribution of 2D space and never considers the noise distribution of 3D space. This study was designed to develop three-dimensional-morphological structure operators (3D MSO) for nuclear medicine imaging and effectively eliminating strike artifacts without reducing image quality. A parallel operation was also used to calculate the minimum background standard deviation of the images for three-dimensional morphological structure operators with the optimal response curve (3D-MSO/ORC). As a result of Jaszczak phantom and rat verification, 3D-MSO/ORC showed better denoising performance and image quality than the 2D-MSO method. Thus, 3D MSO/ORC with a 3 × 3 × 3 mask can reduce noise efficiently and provide stability in FBP images.

Indexed as

AlgorithmsArtifactsAnimalsImage Processing, Computer-AssistedPhantoms, ImagingPositron-Emission TomographyRatsFBPMSOORCPETstrike artifacts

Identifiers

PMID34770534
PMCPMC8587286
OpenAlexW3209320897

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.