ArticleSensors (Basel, Switzerland)2021
Efficient Strike Artifact Reduction Based on 3D-Morphological Structure Operators from Filtered Back-Projection PET Images.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Positron emission tomography (PET) can provide functional images and identify abnormal metabolic regions of the whole-body to effectively detect tumor presence and distribution. The filtered back-projection (FBP) algorithm is one of the most common images reconstruction methods. However, it will generate strike artifacts on the reconstructed image and affect the clinical diagnosis of lesions. Past studies have shown reduction in strike artifacts and improvement in quality of images by two-dimensional morphological structure operators (2D-MSO). The morphological structure method merely processes the noise distribution of 2D space and never considers the noise distribution of 3D space. This study was designed to develop three-dimensional-morphological structure operators (3D MSO) for nuclear medicine imaging and effectively eliminating strike artifacts without reducing image quality. A parallel operation was also used to calculate the minimum background standard deviation of the images for three-dimensional morphological structure operators with the optimal response curve (3D-MSO/ORC). As a result of Jaszczak phantom and rat verification, 3D-MSO/ORC showed better denoising performance and image quality than the 2D-MSO method. Thus, 3D MSO/ORC with a 3 × 3 × 3 mask can reduce noise efficiently and provide stability in FBP images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.