Evidence map›Paper›PMID 34766083›Full record

ArticleJSES international2021

Clinical and radiographic outcomes of reverse shoulder arthroplasty using a hybrid baseplate fixation mechanism.

Lionel Neyton, Ana Nigues, Floris Van Rooij, Sheng Zhang, Philippe Collin

Abstract read
In one paragraph

Article in JSES international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lionel NeytonRamsay Santé, Hôpital Privé Jean Memoz, Centre Orthopédique Santy, Lyon, France.
Ana NiguesRamsay Santé, Hôpital Privé Jean Memoz, Centre Orthopédique Santy, Lyon, France.
Floris Van RooijReSurg SA, Nyon, Switzerland.
Sheng ZhangWangjing Hospital of China Academy of Chinese Medical Sciences, Beijing, China.
Philippe CollinClinique Victor HUGO, Paris, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDespite the success of reverse shoulder arthroplasty (RSA), complication rates remain high (13% to 25%), due to instability, infection, and glenoid component loosening, which can lead to revision. The aim of the present study was to report the early clinical outcomes of RSA using a new hybrid baseplate design, in comparison with the literature on other common RSA baseplates.

methodsThe authors retrospectively analyzed the records of 142 patients (142 shoulders) who underwent primary RSA using a hybrid baseplate design by the senior surgeons between May 2014 and December 2018. Preoperative and postoperative assessments included the Constant score (CS) and range of motion, including active forward elevation, external rotation, and internal rotation.

resultsOf the initial cohort of 142 patients, 13 were lost to follow-up (8.6%), 2 died (1.3%), and 8 required reoperations with implant removal (5.3%). The remaining 119 patients comprised 71 women (60%) and 48 men (40%), aged 73.6 ± 7.3 years at index surgery, 43 of whom required bony increased offset (36%). At a minimum follow-up of 2 years, the CS improved by 37.3 ± 16.1, active forward elevation increased by 51.2° ± 38.1°, external rotation increased by 16.4° ± 25.0°, and internal rotation increased by 1.5 ± 3.2.

conclusionAt a minimum follow-up of 2 years after RSA using a new hybrid baseplate system, the CS and range of motion were satisfactory and comparable to those in recent systematic reviews. The findings of this study suggest that this hybrid baseplate system provides satisfactory outcomes in the short term, although longer follow-up studies are needed to validate its long-term efficacy.

Indexed as

BaseplateClinical outcomesComplicationsGlenoid looseningRange of motionReverse shoulder arthroplastyRevisionsShort term