ArticleJSES international2021
Three-part humeral head fractures treated with a definite construct of blocked threaded wires: finite element and parametric optimization analysis.
Article in JSES international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- Enovis SMR reverse shoulder arthroplasty for complex proximal humerus fractures in patients over 80 years of age.Journal of shoulder and elbow arthroplasty · 2026Article
- External fixation versus reverse shoulder arthroplasty for proximal humerus fractures in the elderly: a retrospective comparative study.Archives of orthopaedic and trauma surgery · 2026Article
- A standardized construct of blocked threaded wires for treating complex three-part proximal humerus fractures. A long-term follow-up of a previously published series.JSES international · 2026Article
- Three- or four-part proximal humeral fractures in middle-aged and active elderly group of patients: a narrative review of treatment options.Annals of joint · 2024Review
- Humeral Head Three-Part Posterior Fracture-Dislocation Reduced through a Posterior Approach and Fixed with Blocked Threaded Wires: A Consecutive Case Series.Medicina (Kaunas, Lithuania) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMini open reduction and percutaneous fixation of three-part humeral head fracture with blocked threaded wires has demonstrated functional results similar to locking plates or intramedullary nails but with significantly lower major complication rate. In the context of three-part humeral head fractures, we performed a parametric optimization through a finite element analysis of a recently published construct to verify if the encouraging clinical results can be supported by a more rigorous investigation from a mechanical viewpoint. MATERIALS AND
methodsThe 2-dimensional geometry of a three-part proximal humerus fracture synthetized with a system of blocked threaded wires was created. Tension/bending/shear and compression load tests were simulated. A parametric optimization analysis was performed considering four design parameters (height of wire couples; wire material; interdistance between two wires). Eighteen simulations were carried out. Additional analyses were performed also considering a varying diameter of the external rod.
resultsFour points where the largest gap occurs and three points associated with the highest stress concentration were considered. As per the tension/bending/shear loading, a slight gap increase was observed in two different points (8.494 μm; 7.540 μm), while a slight decrease was detected along the greater tuberosity fracture line (1.445 μm). The maximum von Mises stress up to 64.4 MPa was achieved in the humeral head. As per the compression loading, the gap increased along the greater tuberosity fracture line (1.445 μm; 7.545μm); the maximum von Mises stress attains the value of 64.42 MPa. The smallest gap distance (15.37μm) and the lowest von Mises stress (51.51 MPa) were obtained in two different alternative constructs. The diameter of the external rod had no significant effect.
conclusionsThe studied construct is biomechanically valid; it only allows micromovements (one-thousandth of the characteristic humerus size) that are not able to cause humeral head rotation and translation. Furthermore, the construct generates acceptable pressure stresses on sensible areas of the fractured humeral head. Compared to the original construct, we propose to space the pair of horizontal wires for the great tuberosity by at least 1 cm.
Indexed as