Evidence map›Paper›PMID 34766074›Full record

ArticleJSES international2021

Three-part humeral head fractures treated with a definite construct of blocked threaded wires: finite element and parametric optimization analysis.

Stefano Gumina, Vittorio Candela, Arianna Cacciarelli, Eleonora Iannuzzi, Giovanni Formica, Walter Lacarbonara

Open access · goldAbstract read
In one paragraph

Article in JSES international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Stefano GuminaDepartment of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, Istituto Clinico Ortopedico Traumatologico (ICOT), Latina, Italy.
Vittorio CandelaDepartment of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, Istituto Clinico Ortopedico Traumatologico (ICOT), Latina, Italy.
Arianna CacciarelliDepartment of Structural Engineering, Sapienza University of Rome, Rome, Italy.
Eleonora IannuzziDepartment of Structural Engineering, Sapienza University of Rome, Rome, Italy.
Giovanni FormicaDepartment of Architecture, Roma Tre University, Rome, Italy.
Walter LacarbonaraDepartment of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, Istituto Clinico Ortopedico Traumatologico (ICOT), Latina, Italy.
Sapienza University of Rome · ITRoma Tre University · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMini open reduction and percutaneous fixation of three-part humeral head fracture with blocked threaded wires has demonstrated functional results similar to locking plates or intramedullary nails but with significantly lower major complication rate. In the context of three-part humeral head fractures, we performed a parametric optimization through a finite element analysis of a recently published construct to verify if the encouraging clinical results can be supported by a more rigorous investigation from a mechanical viewpoint. MATERIALS AND

methodsThe 2-dimensional geometry of a three-part proximal humerus fracture synthetized with a system of blocked threaded wires was created. Tension/bending/shear and compression load tests were simulated. A parametric optimization analysis was performed considering four design parameters (height of wire couples; wire material; interdistance between two wires). Eighteen simulations were carried out. Additional analyses were performed also considering a varying diameter of the external rod.

resultsFour points where the largest gap occurs and three points associated with the highest stress concentration were considered. As per the tension/bending/shear loading, a slight gap increase was observed in two different points (8.494 μm; 7.540 μm), while a slight decrease was detected along the greater tuberosity fracture line (1.445 μm). The maximum von Mises stress up to 64.4 MPa was achieved in the humeral head. As per the compression loading, the gap increased along the greater tuberosity fracture line (1.445 μm; 7.545μm); the maximum von Mises stress attains the value of 64.42 MPa. The smallest gap distance (15.37μm) and the lowest von Mises stress (51.51 MPa) were obtained in two different alternative constructs. The diameter of the external rod had no significant effect.

conclusionsThe studied construct is biomechanically valid; it only allows micromovements (one-thousandth of the characteristic humerus size) that are not able to cause humeral head rotation and translation. Furthermore, the construct generates acceptable pressure stresses on sensible areas of the fractured humeral head. Compared to the original construct, we propose to space the pair of horizontal wires for the great tuberosity by at least 1 cm.

Indexed as

biomechanical evaluation of pinning techniqueblocked threaded wiresexternal fixatorgold standard for proximal humerus fracturepercutaneous pinning techniqueProximal humerus fracturethree-part humeral head fracture

Identifiers

PMID34766074
PMCPMC8568808
OpenAlexW3195827398

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.