Evidence map›Paper›PMID 34765776›Full record

ArticleHeliyon2021

Diagnostic accuracy of urine dipstick testing for albumin-to-creatinine ratio and albuminuria: A systematic review and meta-analysis.

Jhonatan R Mejia, Jose Ernesto Fernandez-Chinguel, Gandy Dolores-Maldonado, Naysha Becerra-Chauca, Sergio Goicochea-Lugo, Percy Herrera-Añazco, Jessica Hanae Zafra-Tanaka, Alvaro Taype-Rondan

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.

  1. Pooled it
  2. Albuminuria or proteinuria in glomerular disease and CKD-which one to use?Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 1 country.

Jhonatan R MejiaUniversidad Nacional del Centro del Perú, Sociedad Científica de Estudiantes de Medicina del Centro, Huancayo, Peru.
Jose Ernesto Fernandez-ChinguelUniversidad San Martin de Porres, Chiclayo, Peru.
Gandy Dolores-MaldonadoInstituto de Evaluación de Tecnologías en Salud e Investigación-IETSI, Lima, Peru.
Naysha Becerra-ChaucaInstituto de Evaluación de Tecnologías en Salud e Investigación-IETSI, Lima, Peru.
Sergio Goicochea-LugoInstituto de Evaluación de Tecnologías en Salud e Investigación-IETSI, Lima, Peru.
Percy Herrera-AñazcoInstituto de Evaluación de Tecnologías en Salud e Investigación-IETSI, Lima, Peru.
Jessica Hanae Zafra-TanakaUniversidad Científica del Sur, Escuela de Medicina, Lima, Peru.
Alvaro Taype-RondanUniversidad San Ignacio de Loyola, Unidad de Investigación para la Generación y Síntesis de Evidencias en Salud, Lima, Peru.
EsSALUD · PEUniversidad Científica del Sur · PEUniversidad de San Martín de Porres · PEUniversidad Nacional del Centro del Perú · PEUniversidad Privada San Juan Bautista · PEUniversidad San Ignacio de Loyola · PE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe accuracy of urine dipsticks to detect increased albuminuria is uncertain. We aimed to assess the diagnostic accuracy of urine dipsticks for detecting albuminuria.

methodsA systematic review of studies that assessed the diagnostic accuracy of urine dipstick testing for detecting albuminuria has been conducted (using as reference standard the albuminuria in a 24-hour sample or the albumin-to-creatinine ratio) in Scopus, PubMed, and Google Scholar. The risk of bias of the included studies has been assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Whenever possible, we performed meta-analyses for sensitivity and specificity. The certainty of the evidence has also been assessed using the Grading of Recommendations Assessment, Development, and Evaluation methodology.

resultsA total of 14 studies have been included in this review, having assessed all albumin-to-creatinine ratio (ACR) as assessed standard. Each study used different dipstick types. The resulting pooled sensitivity and specificity for each cutoff point were as follows: for ACR >30 mg/g (13 studies): 0.82 (95% confidence interval: 0.76-0.87) and 0.88 (0.83-0.91); for ACR 30-300 mg/g (7 studies): 0.72 (0.68-0.77) and 0.82 (0.76-0.89); and for ACR >300 mg/g (7 studies): 0.84 (0.71-0.90) and 0.97 (0.95-0.99), respectively. An overall high risk of bias, an important heterogeneity in all pooled analysis, and a very low certainty of the evidence have been found.

conclusionsPooled sensitivity and specificity of urine dipsticks have been calculated for different ACR cutoff points. However, the dipstick types differed across studies, and the certainty of the evidence was very low. Thus, further well-designed studies are needed to reach more confident estimates and to assess accuracy differences across dipstick types. REGISTRATION: PROSPERO (CRD42019124637).

Indexed as

AlbuminuriaChronicRenal insufficiencySensitivity and specificity

Identifiers

PMID34765776
PMCPMC8571083
OpenAlexW3209352527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.