Evidence map›Paper›PMID 34765749›Full record

ArticlePhysics and imaging in radiation oncology2021

Intra-fraction motion monitoring during fast modulated radiotherapy delivery in a closed-bore gantry linac.

Laurence Delombaerde, Saskia Petillion, Caroline Weltens, Tom Depuydt

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Laurence DelombaerdeDepartment of Oncology, KU Leuven, Herestraat 49, Leuven 3000, Belgium.
Saskia PetillionDepartment of Radiation Oncology, University Hospitals Leuven, Herestraat 49, Leuven 3000, Belgium.
Caroline WeltensDepartment of Oncology, KU Leuven, Herestraat 49, Leuven 3000, Belgium.
Tom DepuydtDepartment of Oncology, KU Leuven, Herestraat 49, Leuven 3000, Belgium.
KU Leuven · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeNew closed-bore linacs allow for highly streamlined workflows and fast treatment delivery resulting in brief treatment sessions. Motion management technology has only recently been integrated inside the bore, yet is required in future online adaptive workflows. We measured patient motion during every step of the workflow: image acquisition, evaluation and treatment delivery using surface scanning. MATERIALS AND

methodsNineteen patients treated for breast, lung or esophageal cancer were prospectively monitored from the end of setup to the end of treatment delivery in the Halcyon linac (Varian Medical Systems). Motion of the chest was tracked by way of 6 degrees-of-freedom surface tracking. Baseline drift and rate of drift were determined. The influence of fraction number, patient and fraction duration were analyzed with multi-way ANOVA.

resultsMedian fraction duration was 4 min 48 s including the IGRT procedure (kV-CBCT acquisition and evaluation) (N = 221). Baseline drift at the end of the fraction was -1.8 ± 1.5 mm in the anterior-posterior, -0.0 ± 1.7 mm in the cranio-caudal direction and 0.1 ± 1.8 mm in the medio-lateral direction of which 75% occurred during the IGRT procedure. The highest rate of baseline drift was observed between 1 and 2 min after the end of patient setup (-0.62 mm/min). Baseline drift was patient and fraction duration dependent (p < 0.001), but fraction number was not significant (p = 0.33).

conclusionEven during short treatment sessions, patient baseline drift is not negligible. Drift is largest during the initial minutes after completion of patient setup, during verification imaging and evaluation. Patients will need to be monitored during extended contouring and re-planning procedures in online adaptive workflows.

Indexed as

Adaptive radiotherapyBaseline driftClosed-boreIMRTIntra-fraction monitoringOptical surface scanningVMAT