Evidence map›Paper›PMID 34763581›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2021

Experimental validation of acoustic and thermal modeling in heterogeneous phantoms using the hybrid angular spectrum method.

Megan Hansen, Douglas Christensen, Allison Payne

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Integrating temperature-dependent tissue properties into focused ultrasound computational models for enhanced treatment planning.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2026
    Article
  2. Article
  3. Article
  4. Evaluation of acoustic-thermal simulations of in vivo magnetic resonance guided focused ultrasound ablative therapy.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2024
    Article
  5. The influence of bone model geometries on the determination of skull acoustic properties.International journal for numerical methods in biomedical engineering · 2023
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Megan HansenDepartment of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA.
Douglas ChristensenDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
Allison PayneDepartment of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA.ORCID 0000-0002-7724-5001

Funding

Validation and translation of a non-invasive, MR-guided breast cancer therapyR37CA224141 · NCI · UNIVERSITY OF UTAH · PI PAYNE, ALLISON · 2018 to 2024
$3.7M
NCI NIH HHS R37 CA224141
6 · The paper itself

Abstract

purposeThe aim was to quantitatively validate the hybrid angular spectrum (HAS) algorithm, a rapid wave propagation technique for heterogeneous media, with both pressure and temperature measurements.

methodsHeterogeneous tissue-mimicking phantoms were used to evaluate the accuracy of the HAS acoustic modeling algorithm in predicting pressure and thermal patterns. Acoustic properties of the phantom components were measured by a through-transmission technique while thermal properties were measured with a commercial probe. Numerical models of each heterogeneous phantom were segmented from 3D MR images. Cylindrical phantoms 30-mm thick were placed in the pre-focal field of a focused ultrasound beam and 2D pressure measurements obtained with a scanning hydrophone. Peak pressure, full width at half maximum, and normalized root mean squared difference (RMSDn) between the measured and simulated patterns were compared. MR-guided sonications were performed on 150-mm phantoms to obtain MR temperature measurements. Using HAS-predicted power density patterns, temperature simulations were performed. Experimental and simulated temperature patterns were directly compared using peak and mean temperature plots, RMSDn metrics, and accuracy of heating localization.

resultsThe average difference between simulated and hydrophone-measured peak pressures was 9.0% with an RMSDn of 11.4%. Comparison of the experimental MRI-derived and simulated temperature patterns showed RMSDn values of 10.2% and 11.1% and distance differences between the centers of thermal mass of 2.0 and 2.2 mm.

conclusionsThese results show that the computationally rapid hybrid angular spectrum method can predict pressure and temperature patterns in heterogeneous models, including uncertainties in property values and other parameters, to within approximately 10%.

Indexed as

AcousticsImaging, Three-DimensionalAlgorithmsMagnetic Resonance ImagingPhantoms, ImagingAcoustic modelingacoustic propertieshigh-intensity focused ultrasoundtissue-mimicking phantoms

Identifiers

PMID34763581
PMCPMC8672870

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked