Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements.

Ching-Hsuan Huang, Jiayang He, Elena Austin, Edmund Seto, Igor Novosselov

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ching-Hsuan HuangDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America.ORCID 0000-0002-7283-7032
Jiayang HeDepartment of Mechanical Engineering, College of Engineering, University of Washington, Seattle, Washington, United States of America.ORCID 0000-0002-9740-791X
Elena AustinDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America.
Edmund SetoDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America.
Igor NovosselovDepartment of Mechanical Engineering, College of Engineering, University of Washington, Seattle, Washington, United States of America.

Funding

XENOBIOTIC BIOTRANSFORMATION AND DISPOSITIONP30ES007033 · NIEHS · UNIVERSITY OF WASHINGTON · PI Sheela Sathyanarayana · 1995 to 2026
$42.5M
Development of the Total Exposure Monitoring Unit (TEMU) for Pediatric AsthmaU01EB021923 · NIBIB · UNIVERSITY OF WASHINGTON · PI SETO, EDMUND · 2015 to 2018
$1.9M
Validation and application of portable particulate device in the UW Twin RegistryR33ES024715 · NIEHS · UNIVERSITY OF WASHINGTON · PI DUNCAN, GLEN E, SETO, EDMUND · 2017 to 2019
$1.5M
Validation and application of portable particulate device in the UW Twin RegistryR21ES024715 · NIEHS · UNIVERSITY OF WASHINGTON · PI DUNCAN, GLEN E, SETO, EDMUND · 2015 to 2016
$387k
NIBIB NIH HHS U01 EB021923NIEHS NIH HHS P30 ES007033NIEHS NIH HHS R21 ES024715NIEHS NIH HHS R33 ES024715
6 · The paper itself

Abstract

Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scattering depends on particles' properties such as size, shape, and complex index of refraction (CRI) as well as environmental parameters such as temperature and relative humidity (RH). As low-cost PM sensors are not able to resolve individual particles, there is a need to characterize and calibrate sensors' performance under a controlled environment. Here, we present improved calibration algorithms for Plantower PMS A003 sensor for mass indices and size-resolved number concentration. An aerosol chamber experimental protocol was used to evaluate sensor-to-sensor data reproducibility. The calibration was performed using four polydisperse test aerosols. The particle size distribution OEM calibration for PMS A003 sensor did not agree with the reference single particle sizer measurements. For the number concentration calibration, the linear model without adjusting for the aerosol properties and environmental conditions yields an absolute error (NMAE) of ~ 4.0% compared to the reference instrument. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM's mass concentrations estimates with NMAE within 5.0%. The calibration algorithms developed in this study can be used in indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios where field calibration might be challenging.

Indexed as

AerosolsAir PollutantsAir Pollution, IndoorAlgorithmsCalibrationEnvironmental MonitoringEnvironment, ControlledHumansHumidityLinear ModelsOccupational ExposureParticle SizeParticulate MatterRefractometryReproducibility of ResultsTemperatureAerosolsAir PollutantsParticulate Matter

Identifiers

PMID34762676
PMCPMC8584671

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.