ArticleKorean journal of neurotrauma2021
Efficacy of 3D-Printed Titanium Mesh-Type Patient-Specific Implant for Cranioplasty.
Article in Korean journal of neurotrauma, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 16 citations in OpenAlex.
- Beyond the bone flap: integrating biomarkers, imaging, and emerging technologies in the surgical continuum of acute subdural hematoma (ASDH).Annals of medicine and surgery (2012) · 2026Review
- Outcomes of cranioplasty with customized artificial bone flap made by 3D printing technique in patients with aneurysmal subarachnoid hemorrhage.Journal of cerebrovascular and endovascular neurosurgery · 2026Article
- Comparative Safety and Efficacy of Patient-Specific Versus Hand-Molded Implants in Cranioplasty: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2025Review
- Cranial reconstruction in the literature: A CiteSpace visualized bibliometric analysis.Neurosurgical review · 2025Article
- Unseparated Temporal Muscle and Duramater Cranioplasty Methods Following Decompressive Craniectomy: Technical Note.Korean journal of neurotrauma · 2024Article
- Risk Factor Analysis of Cryopreserved Autologous Bone Flap Resorption in Adult Patients Undergoing Cranioplasty with Volumetry Measurement Using Conventional Statistics and Machine-Learning Technique.Journal of Korean Neurosurgical Society · 2024Article
- Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report.Archives of craniofacial surgery · 2022Article
- [Application of two-stage operation on free latissimus dorsi myocutaneous flap transplantation and skull contour reconstruction in treatment of head titanium mesh exposure with soft tissue infection].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveAutologous bone grafting for cranioplasty is associated with a high infection rate and bone absorption. Synthetic implant materials for cranioplasty have been developed. In this study, we evaluated the efficacy of titanium mesh-type patient-specific implants (PSIs) for patients with skull defects using the dice similarity coefficient (DSC), clinical outcomes, and artifacts caused by implants.
methodsThis retrospective study included 40 patients who underwent cranioplasty with a titanium mesh PSI at our institution. Based on preoperative and postoperative computed tomography scans, we calculated DSC and artifacts.
resultsThe calculated DSC of 40 patients was 0.75, and the noise was 13.89% higher in the region of interest (ROI) near the implanted side (average, 7.64 hounsfield unit [HU]±2.62) than in the normal bone (average, 6.72 HU±2.35). However, the image signal-to-noise ratio did not significantly differ between the ROI near the implanted side (4.77±1.78) and normal bone (4.97±1.88). The patients showed no significant perioperative complications that required a secondary operation.
conclusionTitanium mesh-type PSIs for cranioplasty have excellent DSC values with lower artifacts and complication rates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials