ArticleJournal of contemporary brachytherapy2021
3D-printed surface applicators for brachytherapy: a phantom study.
Article in Journal of contemporary brachytherapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Tailored contact brachytherapy for challenging facial basal cell carcinomas: clinical results of 3D printing technology implementation.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026Article
- 3D-Printed Devices in Interventional Radiotherapy (Brachytherapy) Applications: A Literature Review.Journal of personalized medicine · 2025Review
- Shielding disc backscatter calculations in intraoperative radiotherapy using a Monte Carlo simulation based on the method of energy spectra reconstruction.Scientific reports · 2025Article
- Brachytherapy and 3D printing for skin cancer: A review paper.Journal of contemporary brachytherapy · 2024Review
- Review
- Personalized Superficial HDR Brachytherapy-Dosimetric Verification of Dose Distribution with Lead Shielding of Critical Organs in the Head and Neck Region.Journal of personalized medicine · 2022Article
- Accuracy of the doses computed by the Eclipse treatment planning system near and inside metal elements.Scientific reports · 2022Article
- 3D printing of individual skin brachytherapy applicator: design, manufacturing, and early clinical results.Journal of contemporary brachytherapy · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeBrachytherapy is a great alternative for restrictive surgical procedures in facial cancers. Moreover, dose distribution is more beneficial compared with teleradiotherapy during treatment of lesions located on anatomical curves. However, repetitiveness of application is the main issue associated with using commercial applicators. The risk of its displacement is very unfavorable due to large dose gradients in brachytherapy. The aim of this study was to develop a process of preparation of applicators using 3D printing technology. MATERIAL AND
methodsIn planning system, circular volumes near the nose, eye, and ear were determined on transverse layers of an anthropomorphic phantom. Next, boluses with a thickness of 5 mm and 10 mm were designed for each of the layers. Channels in the 10 mm bolus were designed in such a way to place the catheters into the layers. Prepared applicators were printed using polylactic acid (PLA) filament. Plans to irradiate the films for their calibration and plans for treatment prepared in the treatment planning system were conducted. A special phantom was created to calibrate the radiochromic films. Dose distribution around the designed applicators was measured in an anthropomorphic phantom using films within the layers of phantom. Comparison of doses was performed with two-dimensional gamma analysis using OmniPro I'mRT software.
resultsThe obtained results confirmed compliance of the planned and measured doses in 92%; the analysis of gamma parameter showed 1%/1 mm for acceptability level of 95%. Moreover, the initial dosimetric analysis for gamma criteria with 2%/2 mm showed compliance at 99%.
conclusionsThe results of the present study confirm potential clinical usefulness of the applicators obtained with the use of 3D printing for brachytherapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials