Evidence map›Paper›PMID 34759980›Full record

ArticleJournal of contemporary brachytherapy2021

3D-printed surface applicators for brachytherapy: a phantom study.

Grzegorz Biele da, Anna Marach, Marek Boehlke, Grzegorz Zwierzchowski, Julian Malicki

Open access · goldAbstract read
In one paragraph

Article in Journal of contemporary brachytherapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Tailored contact brachytherapy for challenging facial basal cell carcinomas: clinical results of 3D printing technology implementation.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
    Article
  2. Review
  3. Article
  4. Brachytherapy and 3D printing for skin cancer: A review paper.Journal of contemporary brachytherapy · 2024
    Review
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Grzegorz Biele daElectroradiology Department, Poznan University of Medical Sciences, Poznan´, Poland.
Anna MarachMedical Physics Department, Greater Poland Cancer Centre, Poznan´, Poland.
Marek BoehlkeMedical Physics Department, West Pomeranian Oncology Center, Strzałowska, Szczecin, Poland.
Grzegorz ZwierzchowskiElectroradiology Department, Poznan University of Medical Sciences, Poznan´, Poland.
Julian MalickiElectroradiology Department, Poznan University of Medical Sciences, Poznan´, Poland.
Greater Poland Cancer Center · PLPomeranian Medical University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeBrachytherapy is a great alternative for restrictive surgical procedures in facial cancers. Moreover, dose distribution is more beneficial compared with teleradiotherapy during treatment of lesions located on anatomical curves. However, repetitiveness of application is the main issue associated with using commercial applicators. The risk of its displacement is very unfavorable due to large dose gradients in brachytherapy. The aim of this study was to develop a process of preparation of applicators using 3D printing technology. MATERIAL AND

methodsIn planning system, circular volumes near the nose, eye, and ear were determined on transverse layers of an anthropomorphic phantom. Next, boluses with a thickness of 5 mm and 10 mm were designed for each of the layers. Channels in the 10 mm bolus were designed in such a way to place the catheters into the layers. Prepared applicators were printed using polylactic acid (PLA) filament. Plans to irradiate the films for their calibration and plans for treatment prepared in the treatment planning system were conducted. A special phantom was created to calibrate the radiochromic films. Dose distribution around the designed applicators was measured in an anthropomorphic phantom using films within the layers of phantom. Comparison of doses was performed with two-dimensional gamma analysis using OmniPro I'mRT software.

resultsThe obtained results confirmed compliance of the planned and measured doses in 92%; the analysis of gamma parameter showed 1%/1 mm for acceptability level of 95%. Moreover, the initial dosimetric analysis for gamma criteria with 2%/2 mm showed compliance at 99%.

conclusionsThe results of the present study confirm potential clinical usefulness of the applicators obtained with the use of 3D printing for brachytherapy.

Indexed as

3D printingapplicator designsuperficial brachytherapy

Identifiers

PMID34759980
PMCPMC8565625
OpenAlexW3210048127

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.