Evidence map›Paper›PMID 34759278›Full record

ArticleScientific reports2021

A randomized cross-over trial investigating differences in 24-h personal air and skin temperatures using wearable sensors between two climatologically contrasting settings.

Andria Constantinou, Stavros Oikonomou, Corina Konstantinou, Konstantinos C Makris

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andria ConstantinouCyprus International Institute for Environmental and Public Health, Cyprus University of Technology, Limassol, Cyprus.
Stavros OikonomouCyprus International Institute for Environmental and Public Health, Cyprus University of Technology, Limassol, Cyprus.
Corina KonstantinouCyprus International Institute for Environmental and Public Health, Cyprus University of Technology, Limassol, Cyprus.
Konstantinos C MakrisCyprus International Institute for Environmental and Public Health, Cyprus University of Technology, Limassol, Cyprus. konstantinos.makris@cut.ac.cy.

Funding

Horizon 2020 Framework Programme 810995
6 · The paper itself

Abstract

The influence of elevated air temperatures recorded in various urban microenvironments in adversely impacting biologically relevant disease end points has not yet been extensively tackled. This study is a post hoc analysis of the TEMP pilot trial, a randomized 2 × 2 cross-over trial that examined changes in metabolic and stress hormonal profiles of healthy adults in two settings (urban vs. rural) with distinctly different climatological characteristics during the Mediterranean summer. This analysis aimed to study the association between the 24-h personal air or skin temperature sensor measurements and the diary-based location type (indoors vs. outdoors) in urban (seaside) vs. rural (higher in altitude) microenvironments. Out of 41 eligible participants, a total of 37 participants were included in this post-hoc TEMP trial analysis. Wearable sensors recorded personal air temperature, skin temperature, and activity (as a surrogate marker of physical activity) in each setting, while a time-stamped personal diary recorded the types of indoor or outdoor activities. Temperature peaks during the 24-h sampling period were detected using a peak finding algorithm. Mixed effect logistic regression models were fitted for the odds of participant location (being indoors vs. outdoors) as a function of setting (urban vs. rural) and sensor-based personal temperature data (either raw temperature values or number of temperature peaks). During the study period (July-end of September), median [interquartile range, IQR] personal air temperature in the rural (higher altitude) settings was 1.5 °C lower than that in the urban settings (27.1 °C [25.4, 29.2] vs. 28.6 °C [27.1, 30.5], p < 0.001), being consistent with the Mediterranean climate. Median [IQR] personal air temperature in indoor (micro)environments was lower than those in outdoors (28.0 °C [26.4, 30.3] vs 28.5 °C [26.8, 30.7], p < 0.001). However, median [IQR] skin temperature was higher in indoor (micro)environments vs. outdoors (34.8 °C [34.0, 35.6] and 33.9 °C [32.9, 34.8], p < 0.001) and the number of both personal air and skin temperature peaks was higher indoors compared to outdoors (median [IQR] 3.0 [2.0,4.0] vs 1.0 [1.0,1.3], p < 0.007, for the skin sensors). A significant association between the number of temperature peaks and indoor location types was observed with either the personal air sensor (OR 3.1; 95% CI 1.2-8.2; p = 0.02) or the skin sensor (OR 3.7; 95% CI 1.4-9.9; p = 0.01), suggesting higher number of indoor air temperature fluctuations. Amidst the global climate crisis, more population health studies or personalized medicine approaches that utilize continuous tracking of individual-level air/skin temperatures in both indoor/outdoor locations would be warranted, if we were to better characterize the disease phenotype in response to climate change manifestations.

Indexed as

ClimateSkin TemperatureAdultCross-Over StudiesCyprusEnvironmental ExposureEnvironmental MonitoringFemaleHumansMaleMiddle AgedPilot ProjectsRandom AllocationRural PopulationUrban PopulationWearable Electronic Devices

Identifiers

PMID34759278
PMCPMC8580978

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.