Evidence map›Paper›PMID 34758860›Full record

ArticleJournal of orthopaedic surgery and research2021

Accuracy of one-dimensional templating on linear EOS radiography allows template-directed instrumentation in total knee arthroplasty.

Michael Andreas Finsterwald, Salar Sobhi, Senthuren Isaac, Penelope Scott, Riaz J K Khan, Daniel P Fick

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Michael Andreas FinsterwaldThe Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA, 6009, Australia. michi.finsterwald@sunrise.ch.ORCID http://orcid.org/0000-0002-1924-5388
Salar SobhiThe Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA, 6009, Australia.
Senthuren IsaacThe Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA, 6009, Australia.
Penelope ScottHollywood Private Hospital, Monash Avenue, Nedlands, WA, 6009, Australia.
Riaz J K KhanThe Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA, 6009, Australia.
Daniel P FickThe Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA, 6009, Australia.
Hollywood Private Hospital · AUCurtin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTemplating for total knee arthroplasty (TKA) is routinely performed on two-dimensional standard X-ray images and allows template-directed instrumentation. To date, there is no report on one-dimensional (1D) anteroposterior (AP) templating not requiring specific templating software. We aim to describe a novel technique and explore its reliability, accuracy and potential cost-savings.

methodsWe investigated a consecutive series of TKAs at one institution between January and July 2019. Patients with preoperative low-dose linear AP EOS radiography images were included. Implant component sizes were retrospectively templated on the AP view with the hospitals imaging viewing software by two observers who were blinded to the definitive implant size. Planning accuracy as well as inter- and intra-observer reliability was calculated. Cost-savings were estimated based on the reduction of trays indicated by the 1D templating size estimations.

resultsA total of 141 consecutive TKAs in 113 patients were included. Accuracy of 1D templating was as follows: exact match in 53% femoral and 63% tibial components, within one size in 96% femoral and 98% tibial components. Overall 58% of TKA components were planned correctly and 97% within one size. Inter- and intra-rater reliability was good (κ = 0.66) and very good (κ = 0.82), respectively. This templating process can reduce instrumentation from six to three trays per case and therefore halve sterilisation costs.

conclusionsThe new 1D templating method using EOS AP imaging predicts component sizes in TKA within one size 97% of the time and can halve the number of instrumentation trays and sterilisation costs.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFemurHumansRadiographyReproducibility of ResultsRetrospective StudiesCost analysisCost reductionOne-dimensional templatingTemplate-directed instrumentationTotal knee arthroplastyTotal knee replacementTray reduction

Identifiers

PMID34758860
PMCPMC8579604
OpenAlexW3214151756

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.