ArticleBMC musculoskeletal disorders2021
A biomechanical analysis of anterior cervical discectomy and fusion alone or combined cervical fixations in treating compression-extension injury with unilateral facet joint fracture: a finite element study.
Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.
- Pooled it
- Biomechanical evaluation of a novel cervical interfacet self-locking cage versus ACDF: a goat cadaveric study combined with human CT-based finite element analysis.BMC musculoskeletal disorders · 2026Article
- Biomechanical effects of supplemental posterior cervical stabilization in one-to three-level anterior cervical discectomy and fusion: a finite element analysis of construct length-dependent stress shielding and adjacent segment mechanics.Frontiers in bioengineering and biotechnology · 2026Article
- Treatment Strategy for Subaxial Minimal Facet/Lateral Mass Fractures: A Comprehensive Clinical Review.Journal of clinical medicine · 2025Review
- Does Screw Number of Zero-profile Implants in Fusion Segment Influence Intervertebral Stability?Orthopaedic surgery · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCompression-extension injury with unilateral facet joint fracture is one of the most devastating injuries of subaxial cervical spine. However, it is not yet clear which fixation technique represents the optimal choice in surgical management. This study aims to assess the construct stability at the operative level (C4/C5 cervical spine) following anterior cervical discectomy and fusion (ACDF) alone and combined fixation techniques (posterior-anterior fixations).
methodsA previously validated three-dimensional C2-T1 finite element model were modified to simulate surgical procedures via the anterior-only approach (ACDF) and combined cervical approach [(transarticular screw, lateral mass screw, unilateral pedicle screw, bilateral pedicle screw) + ACDF, respectively] for treating compression-extension injury with unilateral facet joint fracture at C4/C5 level. Construct stability (range of rotation, axial compression displacement and anterior shear displacement) at the operative level was comparatively analyzed.
resultsIn comparison with combined fixation techniques, a wider range of motion and a higher maximum von Mises stress was found in single ACDF. There was no obvious difference in range of motion among transarticular screw and other posterior fixations in the presence of anterior fixation. In addition, the screws inserted by transarticular screw technique had high stress concentration at the middle part of the screw but much less than 500 MPa under different conditions. Furthermore, the variability of von Mises stress in the transarticular screw fixation device was significantly lower than ACDF but no obvious difference compared with other posterior fixations.
conclusionsOf the five fixation techniques, ACDF has proven poor stability and high structural stress. Compared with lateral and pedicle screw, transarticular screw technique was not worse biomechanically and less technically demanding to acquire in clinical practice. Therefore, our study suggested that combined fixation technique (transarticular screw + ACDF) would be a reasonable treatment option to acquire an immediate stabilization in the management of compression-extension injury with unilateral facet joint fracture. However, clinical aspects must also be regarded when choosing a reconstruction method for a specific patient.