Evidence map›Paper›PMID 34750782›Full record

ArticleCardiovascular engineering and technology2022

Hemodynamic Study of a Patient-Specific Intracranial Aneurysm: Comparative Assessment of Tomographic PIV, Stereoscopic PIV, In Vivo MRI and Computational Fluid Dynamics.

Xiaolin Wu, Stefanie Gürzing, Christiaan Schinkel, Merel Toussaint, Romana Perinajová, Pim van Ooij, Saša Kenjereš

Open access · hybridAbstract read
In one paragraph

Article in Cardiovascular engineering and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Xiaolin WuDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
Stefanie GürzingDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
Christiaan SchinkelDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
Merel ToussaintDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
Romana PerinajováDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
Pim van OoijDepartment of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
Saša KenjerešDepartment of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands. S.Kenjeres@tudelft.nl.ORCID 0000-0002-7568-5513
Delft University of Technology · NLJ.M. Burgerscentrum · NLAmsterdam University Medical Centers · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWall shear stress (WSS) is associated with the growth and rupture of an intracranial aneurysm. To reveal their underlying connections, many image-based computational fluid dynamics (CFD) studies have been conducted. However, the methodological validations using both in vivo medical imaging and in vitro optical flow measurements were rarely accompanied in such studies.

methodsIn the present study, we performed a comparative assessment on the hemodynamics of a patient-specific intracranial saccular aneurysm using in vivo 4D Flow MRI, in silico CFD, in vitro stereoscopic and tomographic particle imaging velocimetry (Stereo-PIV and Tomo-PIV) techniques. PIV experiments and CFD were conducted under steady state corresponding to the peak systole of 4D Flow MRI.

resultsThe results showed that all modalities provided similar flow features and overall surface distribution of WSS. However, a large variation in the absolute WSS values was found. 4D Flow MRI estimated a 2- to 4-fold lower peak WSS (3.99 Pa) and a 1.6- to 2-fold lower mean WSS (0.94 Pa) than Tomo-PIV, Stereo-PIV, and CFD. Bland-Altman plots of WSS showed that the differences between PIV-/CFD-based WSS and 4D Flow MRI-based WSS increase with higher WSS magnitude. Such proportional trend was absent in the Bland-Altman comparison of velocity where the resolutions of PIV and CFD datasets were matched to 4D Flow MRI. We also found that because of superior resolution in the out-of-plane direction, WSS estimation by Tomo-PIV was higher than Stereo-PIV.

conclusionsOur results indicated that the differences in spatial resolution could be the main contributor to the discrepancies between each modality. The findings of this study suggest that with current techniques, care should be taken when using absolute WSS values to perform a quantitative risk analysis of aneurysm rupture.

Indexed as

Intracranial AneurysmBlood Flow VelocityHemodynamicsHumansHydrodynamicsMagnetic Resonance ImagingStress, Mechanical4D Flow MRIComputational fluid dynamicsHemodynamicsIntracranial aneurysmParticle image velocimetryWall shear stress

Identifiers

PMID34750782
PMCPMC9197918
OpenAlexW3211761374

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.