Evidence map›Paper›PMID 34750643›Full record

ArticleAnalytical and bioanalytical chemistry2022

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection.

Clarisse E Buensuceso, Brylee David B Tiu, Luke P Lee, Portia Mahal G Sabido, Guillermo M Nuesca, Eugene B Caldona, Florian R Del Mundo, Rigoberto C Advincula

Erratum issuedOpen access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Clarisse E BuensucesoInstitute of Chemistry, College of Science, University of the Philippines Diliman, 1101, Quezon City, Philippines.
Brylee David B TiuDepartment of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Luke P LeeDepartment of Bioengineering, University of California, Berkeley, CA, 94720-1762, USA.
Portia Mahal G SabidoInstitute of Chemistry, College of Science, University of the Philippines Diliman, 1101, Quezon City, Philippines.
Guillermo M NuescaInstitute of Chemistry, College of Science, University of the Philippines Diliman, 1101, Quezon City, Philippines.
Eugene B CaldonaDepartment of Chemical and Biomolecular Engineering and Joint Institute for Advanced Materials, University of Tennessee, Knoxville, TN, 37996, USA.
Florian R Del MundoInstitute of Chemistry, College of Science, University of the Philippines Diliman, 1101, Quezon City, Philippines.
Rigoberto C AdvinculaDepartment of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA. rca41@case.edu.
University of the Philippines Diliman · PHCase Western Reserve University · USJoint Institute for Computational Sciences · USUniversity of California, Berkeley · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH

Indexed as

AdsorptionDengueDengue VirusElectrochemical TechniquesHumansLimit of DetectionMolecular ImprintingMolecularly Imprinted PolymersPhotoelectron SpectroscopyQuartz Crystal Microbalance TechniquesViral Nonstructural ProteinsMolecularly Imprinted PolymersViral Nonstructural ProteinsDengue nonstructural protein 1 (NS1)ElectropolymerizationEpitope imprintingMolecularly imprinted polymersQuartz crystal microbalance

Identifiers

PMID34750643
OpenAlexW3213064521

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.