ArticleBMC veterinary research2021
A pilot study evaluating the Calibrated Automated Thrombogram assay and application of plasma-thromboelastography for detection of hemostatic aberrations in horses with gastrointestinal disease.
Article in BMC veterinary research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Investigation of two different human d-dimer assays in the horse.BMC veterinary research · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCritically ill horses, such as horses with gastrointestinal (GI) disease, often suffer from hemostatic aberrations. Global hemostatic tests examining the initiation of coagulation, clot strength and fibrinolysis, such as the Calibrated Automated Thrombogram (CAT) and plasma-thromboelastography (TEG) have not been evaluated in horses. This study aimed to evaluate CAT and apply plasma-TEG in horses. Test performance of CAT was evaluated on equine platelet poor plasma with intra- and inter-assay variability (CV) and a heparin dilution curve. To examine clinical performance of both tests, group comparisons were assessed comparing healthy horses, horses with mild and severe GI disease with both CAT and plasma-TEG.
resultsFor CAT, intra- and inter-assay CVs were established for lag-time (1.7, 4.7%), endogenous thrombin potential (1.6, 4.6%), peak (2.6, 3.9%) and time to peak (ttPeak) (1.9, 3.4%). Increasing heparin concentrations led to the expected decrease in thrombin generation. In the group comparison analysis, CAT showed significant higher peak (p = 0.04) and ttPeak (p = 0.008) in the severe GI disease group compared to horses with mild GI disease and healthy horses, respectively. Plasma-TEG showed an increased angle (p = 0.032), maximum amplitude (p = 0.017) and shear elastic force (G) (p = 0.017) in the severe GI disease group compared to healthy horses.
conclusionsCAT performed well in horses. Both CAT and plasma-TEG identified hemostatic aberrations in horses with severe GI disease compared to healthy horses. Further studies including more horses, are needed to fully appreciate the use of CAT and plasma-TEG in this species.