Evidence map›Paper›PMID 34749660›Full record

ArticleBMC medical imaging2021

A NIM PET/CT phantom for evaluating the PET image quality of micro-lesions and the performance parameters of CT.

Shujie Lu, Peng Zhang, Chengwei Li, Jie Sun, Wenli Liu, Pu Zhang

Open access · goldAbstract read
In one paragraph

Article in BMC medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Enhancing PET/CT target assessment with porous 3D printed grids: a pilot study.Physical and engineering sciences in medicine · 2026
    Article
  2. Article
  3. Article
  4. Reduction of [EJNMMI physics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Shujie Lu *Center for Medical Metrology, National Institute of Metrology, Beijing, China.
Peng Zhang *Center for Medical Metrology, National Institute of Metrology, Beijing, China.
Chengwei LiCenter for Medical Metrology, National Institute of Metrology, Beijing, China.
Jie SunCenter for Medical Metrology, National Institute of Metrology, Beijing, China.
Wenli LiuCenter for Medical Metrology, National Institute of Metrology, Beijing, China.
Pu ZhangCenter for Medical Metrology, National Institute of Metrology, Beijing, China. zhangpu@nim.ac.cn.
National Institute of Metrology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe commonly used NEMA IEC Body phantom has a number of defects, hindering its application for detecting micro-lesions and measuring the performance parameters of computed tomography (CT). This study aimed to propose a PET/CT phantom designed by National Institute of Metrology (NIM), China, which is capable of simultaneously testing the performance of PET and CT systems, and to evaluate the quality of imaging.

methodsThe phantom developed in the present study, the NIM PET/CT phantom, is composed of a PET imaging module and a CT imaging module, and these modules are connected together through bolts, which can simultaneously measure the imaging performance of PET and CT systems. Hot spheres were filled with 4:1 sphere-to-background activity concentration using

resultsThe imaging quality of the NIM PET/CT phantom and the NEMA IEC Body phantom was relatively consistent. The NIM PET/CT phantom could detect 7 mm spheres without influencing the imaging quality. It was found that PSF reconstruction exhibited to reduce the speed of convergence, the contrast and background variability of spheres (13-28 mm) were significantly improved after two iterations. In addition to improve the image contrast and background variability, TOF could markedly improve the overall image quality and instrument detection limit. TOF-PSF could noticeably reduce noise level, enhance imaging details, and improve quality of imaging.

conclusionsThe results showed that in comparison with the NEMA IEC Body phantom, the NIM PET/CT phantom outperformed in evaluating the PET image quality of micro-lesions and the performance parameters of CT.

Indexed as

Equipment DesignPhantoms, ImagingPositron Emission Tomography Computed TomographyChinaCT performance parametersImage qualityMicro-lesionsPET/CT phantom

Identifiers

PMID34749660
PMCPMC8576981
OpenAlexW3214497571

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.