ArticleAnnals of cardiac anaesthesia
Analyzing the impact of preoperative interrogation of cardiac implantable electronic devices.
Article in Annals of cardiac anaesthesia. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Highlights from the American College of Cardiology and American Heart Association 2024 Guideline for Perioperative Cardiovascular Management for Noncardiac Surgery.Journal of cardiothoracic and vascular anesthesia · 2025Review
- Economic Evaluation of Anesthesiology-Led Cardiac Implantable Electronic Device Service.Healthcare (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Cardiac implantable electronic devices (CIED) are becoming more common for the management of underlying of cardiac dysrhythmias, and more patients with these devices are presenting for cardiac and noncardiac procedures. Methods: We performed a retrospective, cohort, single-center study at a tertiary teaching medical center, gathering 151 patients with CIED undergoing elective and emergent surgeries for the time period between November 2013 and December 2016. We aimed to determine whether patients with CIED had the device interrogated before surgery as recommended by the Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) consensus, whether this lack of compliance led to delay in the holding area before surgery and determine the presence of intra- or postoperative cardiac events in these patients. Results: A total of 76% of patients had interrogation of the device before surgery. Emergent cases were not interrogated as much as elective cases preoperatively (43% vs. 18%, respectively; P < 0.05). In total, 6% of cases had a CIED-related average holding area delay time of 54 minutes. Patients without preoperative device interrogation had more perioperative cardiac events than those who had the device checked (25% vs. 8%, respectively; odds ratio [OR] 0.26; 95% CI, 0.09-0.7, P < 0.013). Conclusions: Our findings suggest that preoperative interrogation of the device plays a significant role to minimize the incidence of perioperative cardiac adverse events. Institutional providers show a lack of compliance with HRS/ASA recommendations for preoperative CIED management. Further research is required to determine if improved compliance to recommendations will lead to enhanced outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials