ArticleJournal of radiation research2022
Safety verification of carbon-ion radiotherapy for patients with cardiac implantable electronic devices (CIEDs).
Article in Journal of radiation research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 2 syntheses or guidelines pooled it, 5 citations in OpenAlex.
- Systematic review of physical and dosimetric criteria for managing CIEDs in radiotherapy: A medical physicist's perspective.Journal of applied clinical medical physics · 2026Pooled it
- A systematic review and meta-analysis on oncological radiotherapy in patients with a cardiac implantable electronic device: Prevalence and predictors of device malfunction in 3121 patients.European journal of clinical investigation · 2023Pooled it
- Assessment of soft error risks to cardiac implantable electronic devices for boron neutron capture therapy using field-programmable gate arrays.Japanese journal of radiology · 2026Article
- The Contribution of Secondary Particles Following Carbon Ion Radiotherapy to Soft Errors in CIEDs.IEEE open journal of engineering in medicine and biology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
According to guidelines, carbon-ion beam therapy is considered to carry a high safety risk for patients with cardiac implantable electronic devices (CIEDs), although the actual impacts remain unclear. In this study, we investigated the safety of carbon-ion beam therapy in patients with CIEDs. Patients with CIEDs who underwent carbon-ion therapy at Gunma University Heavy Ion Medical Center between June 2010 and December 2019 were identified and investigated for abnormalities in the operation of their CIEDs, such as oversensing and resetting during irradiation, and abnormalities in operation after treatment. In addition, the risk of irradiation from carbon-ion beam therapy was evaluated by model simulations. Twenty patients (22 sites) with CIEDs were identified, 19 with pacemakers and one with an implantable cardioverter-defibrillator (ICD). Treatments were completed without any problems, except for one case in which the treatment was discontinued because of worsening of the primary disease. Monte Carlo simulation indicated that the carbon beam irradiation produced neutrons at a constant and high level in the irradiation field. Nevertheless, with the distances between the CIEDs and the irradiation fields in the analyzed cases, the quantity of neutrons at the CIEDs was lower than that within the irradiation. Although carbon-ion beam therapy can be safely administered to patients with CIEDs, it is advisable to perform the therapy with sufficient preparation and backup devices because of the risks involved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.