Evidence map›Paper›PMID 34746040›Full record

Trial reportCanadian journal of gastroenterology & hepatology2021

Optimal Timing of Simethicone Supplement for Bowel Preparation: A Prospective Randomized Controlled Trial.

Zhen-Wen Wu, Sheng-Gang Zhan, Mei-Feng Yang, Yi-Teng Meng, Feng Xiong, Cheng Wei, Ying-Xue Li, Ding-Guo Zhang, Zheng-Lei Xu, Ben-Hua Wu and 4 more

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Canadian journal of gastroenterology & hepatology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Review
  3. Development and validation of a novel scoring system based on a nomogram for predicting inadequate bowel preparation.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2024
    Article
  4. Shortening Oral Simethicone-to-Colonoscopy Interval Increases Bowel Preparation Quality.Medical science monitor : international medical journal of experimental and clinical research · 2024
    Article
  5. Article
  6. [Recent research on the application of defoamers in children undergoing digestive endoscopy].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2023
    Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 2 institutions in 1 country.

Zhen-Wen Wu *Department of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0001-5017-4648
Sheng-Gang Zhan *Department of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-3318-2635
Mei-Feng Yang *Department of Hematology, Yantian District People's Hospital, Shenzhen 518020, Guangdong, China.ORCID 0000-0002-6387-9986
Yi-Teng MengDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-0413-9048
Feng XiongDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-4021-0817
Cheng WeiDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-6373-1826
Ying-Xue LiDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0001-6350-612X
Ding-Guo ZhangDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0001-7728-9672
Zheng-Lei XuDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-5413-7390
Ben-Hua WuDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-9392-9470
Rui-Yue ShiDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0001-9123-2103
Jun YaoDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0002-3472-1602
Li-Sheng WangDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0001-5965-308X
De-Feng LiDepartment of Gastroenterology, Shenzhen People's Hospital, (The Second Clinical Medical College, Jinan University), Shenzhen 518020, Guangdong, China.ORCID 0000-0003-3118-6840
Jinan University · CNShenzhen Bao'an District People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Simethicone (SIM), as an antifoaming agent, has been shown to improve bowel preparation during colonoscopy. However, the optimal timing of SIM addition remained undetermined. We aimed to investigate the optimal timing of SIM addition to polyethylene glycol (PEG) to improve bowel preparation. Methods: Eligible patients were randomly assigned to two groups: the SIM evening group (SIM addition to PEG in the evening of the day prior to colonoscopy) and the SIM morning group (SIM addition to PEG in the morning of colonoscopy). The primary outcome was Bubble Scale (BS). The secondary outcomes were Boston Bowel Preparation Scale (BBPS) and adenoma detection rate (ADR). Results: A total of 419 patients were enrolled in this study. The baseline characteristics of the patients were similar in both groups. No significant differences were observed in terms of BS (8.76 ± 0.90 vs. 8.65 ± 1.16, Conclusions: The SIM addition to PEG in the evening of the day prior to colonoscopy can shorten cecal intubation time and improve BS scores and diminutive ADR of the right colon compared with the SIM addition to PEG in the morning of colonoscopy in bowel preparation.

Indexed as

CecumSimethiconeCatharticsColonoscopyHumansPolyethylene GlycolsProspective StudiesCatharticsPolyethylene GlycolsSimethicone

Identifiers

PMID34746040
PMCPMC8566047
OpenAlexW3209030664

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.