Influence of Clinical and Tumor Factors on Interfraction Setup Errors With Rotation Correction for Vacuum Cushion in Lung Stereotactic Body Radiation Therapy.

Hua Chen, Lingxiang Liu, Hao Wang, Yan Shao, Hengle Gu, Yanhua Duan, Aihui Feng, Ying Huang, Zhiyong Xu

Open access · goldAbstract read
In one paragraph

Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Hua ChenRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Lingxiang LiuDepartment of Oncology, Guangzhou Panyu Central Hospital, Guangzhou, China.
Hao WangRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Yan ShaoRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Hengle GuRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Yanhua DuanRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Aihui FengRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Ying HuangRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Zhiyong XuRadiation Oncology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China.
Shanghai Chest Hospital · CNPanyu District Central Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo explore the influence of clinical and tumor factors over interfraction setup errors with rotation correction for non-small cell lung cancer (NSCLC) stereotactic body radiation therapy (SBRT) patients immobilized in vacuum cushion (VC) to better understand whether patient re-setup could further be optimized with these parameters. MATERIALS AND

methodsThis retrospective study was conducted on 142 NSCLC patients treated with SBRT between November 2017 to July 2019 in the local institute. Translation and rotation setup errors were analyzed in 732 cone-beam computed tomography (CBCT) scans before treatment. Differences between groups were analyzed using independent sample t-test. Logistic regression test was used to analyze possible correlations between patient re-setup and clinical and tumor factors.

resultsMean setup errors were the largest in anterior-posterior (AP) direction (3.2 ± 2.4 mm) compared with superior-inferior (SI) (2.8 ± 2.1 mm) and left-right (LR) (2.5 ± 2.0 mm) directions. The mean values were similar in pitch, roll, and rtn directions. Of the fractions, 83.7%, 90.3%, and 86.6% satisfied setup error tolerance limits in AP, SI, and LR directions, whereas 95% had rotation setup errors of <2° in the pitch, roll, or rtn directions. Setup errors were significantly different in the LR direction when age, body mass index (BMI), and "right

conclusionsAge and BMI, as clinical factors, significantly influenced patient re-setup in the current study, whereas all other clinical and tumor factors were not correlated with patient re-setup. The current study recommends that more attention be paid to setup for elderly patients and patients with larger BMI when immobilized using VC, especially in the left-right direction.

Indexed as

clinical and tumor factorsinterfractionNSCLCSBRTsetup errorvacuum cushion

Identifiers

PMID34745956
PMCPMC8570303
OpenAlexW3209022271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.