Evidence map›Paper›PMID 34745719›Full record

ArticleBiomedical optics express2021

Microscopic optical coherence tomography (mOCT) at 600 kHz for 4D volumetric imaging and dynamic contrast.

Michael Münter, Mario Pieper, Tabea Kohlfaerber, Ernst Bodenstorfer, Martin Ahrens, Christian Winter, Robert Huber, Peter König, Gereon Hüttmann, Hinnerk Schulz-Hildebrandt

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Michael MünterUniversity of Lübeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.ORCID https://orcid.org/0000-0002-8004-3646
Mario PieperUniversity of Lübeck, Institute of Anatomy, Ratzeburger Allee 160, 23562 Lübeck, Germany.
Tabea KohlfaerberMedizinisches Laserzentrum Lübeck GmbH, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.ORCID https://orcid.org/0000-0003-3789-539X
Ernst BodenstorferAustrian Institute of Technology GmbH, Giefinggasse 4, 1210 Vienna, Austria.
Martin AhrensUniversity of Lübeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.
Christian WinterThorlabs GmbH, Maria-Goeppert-Str. 9, 23562 Lübeck, Germany.
Robert HuberUniversity of Lübeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.ORCID https://orcid.org/0000-0001-9785-6574
Peter KönigUniversity of Lübeck, Institute of Anatomy, Ratzeburger Allee 160, 23562 Lübeck, Germany.
Gereon HüttmannUniversity of Lübeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.
Hinnerk Schulz-HildebrandtUniversity of Lübeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.ORCID https://orcid.org/0000-0003-4389-9151
Medizinisches Laserzentrum Lübeck (Germany) · DEGerman Center for Lung Research · DEAustrian Institute of Technology · ATThorlabs (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Volumetric imaging of dynamic processes with microscopic resolution holds a huge potential in biomedical research and clinical diagnosis. Using supercontinuum light sources and high numerical aperture (NA) objectives, optical coherence tomography (OCT) achieves microscopic resolution and is well suited for imaging cellular and subcellular structures of biological tissues. Currently, the imaging speed of microscopic OCT (mOCT) is limited by the line-scan rate of the spectrometer camera and ranges from 30 to 250 kHz. This is not fast enough for volumetric imaging of dynamic processes

Identifiers

PMID34745719
PMCPMC8547980
OpenAlexW3198801194

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.