Evidence map›Paper›PMID 34744319›Full record

ArticleApplied magnetic resonance2021

Evaluation of a Refined Implantable Resonator for Deep-Tissue EPR Oximetry in the Clinic.

Eunice Y Chen, Dan Tse, Huagang Hou, Wilson A Schreiber, Philip E Schaner, Maciej M Kmiec, Kendra A Hebert, Periannan Kuppusamy, Harold M Swartz, Benjamin B Williams

Open access · greenAbstract read
In one paragraph

Article in Applied magnetic resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.5field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Celebration of 80 years of EPR.Applied magnetic resonance · 2024
    Article
  4. Article
  5. Recognising Potential Ambiguities in Measurements of Oxygen in Tissues.Advances in experimental medicine and biology · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Eunice Y ChenSection of Otolaryngology, Department of Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States and Geisel School of Medicine at Dartmouth, Hanover, NH.
Dan TseDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Huagang HouDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Wilson A SchreiberDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Philip E SchanerSection of Radiation Oncology, Department of Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States and Geisel School of Medicine at Dartmouth, Hanover, NH.
Maciej M KmiecDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Kendra A HebertDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Periannan KuppusamyDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Harold M SwartzDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Benjamin B WilliamsDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, United States.
Dartmouth College · USDartmouth–Hitchcock Medical Center · US

Funding

Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
Project 3: Direct & Repeated Measurement of pO2 in Deep-seated Tumors using EPR OP01CA190193 · NCI · DARTMOUTH COLLEGE · PI WILLIAMS, BENJAMIN B · 2015 to 2019
$7.0M
NCI NIH HHS P01 CA190193NIBIB NIH HHS R01 EB004031
6 · The paper itself

Abstract

objectives(1) Summarize revisions made to the implantable resonator (IR) design and results of testing to characterize biocompatibility;(2) Demonstrate safety of implantation and feasibility of deep tissue oxygenation measurement using electron paramagnetic resonance (EPR) oximetry. STUDY

designIn vitro testing of the revised IR and in vivo implantation in rabbit brain and leg tissues.

methodsRevised IRs were fabricated with 1-4 OxyChips with a thin wire encapsulated with two biocompatible coatings. Biocompatibility and chemical characterization tests were performed. Rabbits were implanted with either an IR with 2 oxygen sensors or a biocompatible-control sample in both the brain and hind leg. The rabbits were implanted with IRs using a catheter-based, minimally invasive surgical procedure. EPR oximetry was performed for rabbits with IRs. Cohorts of rabbits were euthanized and tissues were obtained at 1 week, 3 months, and 9 months after implantation and examined for tissue reaction.

resultsBiocompatibility and toxicity testing of the revised IRs demonstrated no abnormal reactions. EPR oximetry from brain and leg tissues were successfully executed. Blood work and histopathological evaluations showed no significant difference between the IR and control groups.

conclusionsIRs were functional for up to 9 months after implantation and provided deep tissue oxygen measurements using EPR oximetry. Tissues surrounding the IRs showed no more tissue reaction than tissues surrounding the control samples. This pre-clinical study demonstrates that the IRs can be safely implanted in brain and leg tissues and that repeated, non-invasive, deep-tissue oxygen measurements can be obtained using in vivo EPR oximetry.

Indexed as

electron paramagnetic resonanceEPRimplantable resonatoroximetry

Identifiers

PMID34744319
PMCPMC8570533
OpenAlexW3182590901

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.