Evidence map›Paper›PMID 34740015›Full record

ArticleJournal of the mechanical behavior of biomedical materials2022

Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters.

Steven P Mell, Markus A Wimmer, Joshua J Jacobs, Hannah J Lundberg

Open access · greenAbstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Are current total knee arthroplasty implants tested and approved for personalised alignment?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Steven P MellRush University Medical Center, USA. Electronic address: steven_p_mell@rush.edu.
Markus A WimmerRush University Medical Center, USA.
Joshua J JacobsRush University Medical Center, USA.
Hannah J LundbergRush University Medical Center, USA.
Rush University Medical Center · US

Funding

The Institute for Translational MedicineUL1TR002389 · NCATS · UNIVERSITY OF CHICAGO · PI Joshua J Jacobs, DAVID O MELTZER · 2017 to 2026
$71.6M
Transition from Acute to Chronic Pain in Total Knee Arthroplasty Patients: Identifying Resilience and Vulnerability ProfilesUM1NS112874 · NINDS · RUSH UNIVERSITY MEDICAL CENTER · PI BURNS, JOHN W., BUVANENDRAN, ASOKUMAR · 2019 to 2022
$9.5M
Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR01AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI HALLAB, NADIM JAMES, LUNDBERG, HANNAH JEAN · 2016 to 2020
$2.3M
Wear Testing for Enhanced Prediction of TKR Clinical PerformanceR01AR059843 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI WIMMER, MARKUS ANTON · 2011 to 2014
$1.4M
NCATS NIH HHS UL1 TR002389NIAMS NIH HHS R01 AR059843NIAMS NIH HHS R01 AR070181NINDS NIH HHS UM1 NS112874
6 · The paper itself

Abstract

Currently, preclinical mechanical wear testing of total knee replacements (TKRs) is done using ideally aligned components using standardized TKR level walking under either force or displacement-control regimes. To understand the influence of implant alignment and testing control regime, we studied the effect of nine component alignment parameters on TKR volumetric wear in silico. We used a computational framework combining Latin Hypercube sampling design of experiments, finite element analysis, and a numerical model of polyethylene wear, to create a predictive model of how component alignment affects wear rate for each control regime. Nine component alignment parameters were investigated, five femoral variables and four tibial variables. To investigate perturbations of the nine implant alignment variables, two separate 300-point designs were executed, one for each control regime. The results were then used to generate surrogate statistical models using stepwise multiple linear regression. Wear at the neutral position was 4.5mm

Indexed as

Arthroplasty, Replacement, KneeWalkingHumansFinite element analysisSurgical alignmentTotal knee replacementUltra high molecular weight polyethylene (UHMWPE)Wear

Identifiers

PMID34740015
PMCPMC8710043
OpenAlexW3209649206

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.