Evidence map›Paper›PMID 34739495›Full record

ArticlePloS one2021

In-silico study of accuracy and precision of left-ventricular strain quantification from 3D tagged MRI.

Ezgi Berberoğlu, Christian T Stoeck, Philippe Moireau, Sebastian Kozerke, Martin Genet

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. In-silico heart model phantom to validate cardiac strain imaging.bioRxiv : the preprint server for biology · 2024
    Article
  3. The relationship between myocardial microstructure and strain in chronic infarction using cardiovascular magnetic resonance diffusion tensor imaging and feature tracking.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ezgi BerberoğluInstitute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.ORCID 0000-0002-4607-8845
Christian T StoeckInstitute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
Philippe MoireauMΞDISIM team, Inria, Palaiseau, France.
Sebastian KozerkeInstitute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
Martin GenetMΞDISIM team, Inria, Palaiseau, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac Magnetic Resonance Imaging (MRI) allows quantifying myocardial tissue deformation and strain based on the tagging principle. In this work, we investigate accuracy and precision of strain quantification from synthetic 3D tagged MRI using equilibrated warping. To this end, synthetic biomechanical left-ventricular tagged MRI data with varying tag distance, spatial resolution and signal-to-noise ratio (SNR) were generated and processed to quantify errors in radial, circumferential and longitudinal strains relative to ground truth. Results reveal that radial strain is more sensitive to image resolution and noise than the other strain components. The study also shows robustness of quantifying circumferential and longitudinal strain in the presence of geometrical inconsistencies of 3D tagged data. In conclusion, our study points to the need for higher-resolution 3D tagged MRI than currently available in practice in order to achieve sufficient accuracy of radial strain quantification.

Indexed as

Biomechanical PhenomenaComputer SimulationHeart VentriclesHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingReproducibility of ResultsSignal-To-Noise RatioVentricular Function, Left

Identifiers

PMID34739495
PMCPMC8570486

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.