Evidence map›Paper›PMID 34738944›Full record

ArticleJournal of synchrotron radiation2021

Time-of-flight photoelectron momentum microscopy with 80-500 MHz photon sources: electron-optical pulse picker or bandpass pre-filter.

G Schönhense, K Medjanik, O Fedchenko, A Zymaková, S Chernov, D Kutnyakhov, D Vasilyev, S Babenkov, H J Elmers, P Baumgärtel and 8 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

G SchönhenseInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
K MedjanikInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
O FedchenkoInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
A ZymakováInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.ORCID 0000-0003-0175-638X
S ChernovInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
D KutnyakhovInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
D VasilyevInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
S BabenkovInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
H J ElmersInstitut für Physik, Johannes Gutenberg Universität, 55128 Mainz, Germany.
P BaumgärtelBESSY II, Helmholtz-Zentrum, 12489 Berlin, Germany.
P GoslawskiBESSY II, Helmholtz-Zentrum, 12489 Berlin, Germany.ORCID 0000-0003-1385-1261
G ÖhrwallMAX IV Laboratory, Lund University, PO Box 118, SE-221 00 Lund, Sweden.
T GrunskeAPE GmbH, 13053 Berlin, Germany.
T KauerhofAPE GmbH, 13053 Berlin, Germany.ORCID 0000-0003-0737-0285
K von VolkmannAPE GmbH, 13053 Berlin, Germany.
M KallmayerSurface Concept GmbH, 55128 Mainz, Germany.
M EllguthSurface Concept GmbH, 55128 Mainz, Germany.
A OelsnerSurface Concept GmbH, 55128 Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The small time gaps of synchrotron radiation in conventional multi-bunch mode (100-500 MHz) or laser-based sources with high pulse rate (∼80 MHz) are prohibitive for time-of-flight (ToF) based photoelectron spectroscopy. Detectors with time resolution in the 100 ps range yield only 20-100 resolved time slices within the small time gap. Here we present two techniques of implementing efficient ToF recording at sources with high repetition rate. A fast electron-optical beam blanking unit with GHz bandwidth, integrated in a photoelectron momentum microscope, allows electron-optical `pulse-picking' with any desired repetition period. Aberration-free momentum distributions have been recorded at reduced pulse periods of 5 MHz (at MAX II) and 1.25 MHz (at BESSY II). The approach is compared with two alternative solutions: a bandpass pre-filter (here a hemispherical analyzer) or a parasitic four-bunch island-orbit pulse train, coexisting with the multi-bunch pattern on the main orbit. Chopping in the time domain or bandpass pre-selection in the energy domain can both enable efficient ToF spectroscopy and photoelectron momentum microscopy at 100-500 MHz synchrotrons, highly repetitive lasers or cavity-enhanced high-harmonic sources. The high photon flux of a UV-laser (80 MHz, <1 meV bandwidth) facilitates momentum microscopy with an energy resolution of 4.2 meV and an analyzed region-of-interest (ROI) down to <800 nm. In this novel approach to `sub-µm-ARPES' the ROI is defined by a small field aperture in an intermediate Gaussian image, regardless of the size of the photon spot.

Indexed as

ARPESmomentum microscopyphotoelectron diffractionpulse pickingtime-of-flight spectroscopy

Identifiers

PMID34738944
PMCPMC8570213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.