Evidence map›Paper›PMID 34734137›Full record

ArticleJournal of spine surgery (Hong Kong)2021

The accuracy of robot-assisted S2 alar-iliac screw placement at two different healthcare centers.

Nathan J Lee, Asham Khan, Joseph M Lombardi, Venkat Boddapati, Paul J Park, Justin Mathew, Eric Leung, Jeffrey P Mullin, John Pollina, Ronald A Lehman

Abstract read
In one paragraph

Article in Journal of spine surgery (Hong Kong), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. The Bedrock technique with triangular titanium rods for spinopelvic fixation and sacroiliac joint fusion: is there a learning curve?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Review
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Nathan J LeeDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Asham KhanDepartment of Neurosurgery, State University of New York, Buffalo, NY, USA.
Joseph M LombardiDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Venkat BoddapatiDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Paul J ParkDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Justin MathewDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Eric LeungDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
Jeffrey P MullinDepartment of Neurosurgery, State University of New York, Buffalo, NY, USA.
John PollinaDepartment of Neurosurgery, State University of New York, Buffalo, NY, USA.
Ronald A LehmanDepartment of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCurrent literature on robot-assisted S2 alar-iliac (S2AI) screw placement shows favorable outcomes and screw accuracy; however, the data is limited by a few retrospective, single-surgeon studies. To the author's knowledge, this is the first multicenter study which evaluates the accuracy of robot-assisted S2AI screws.

methodsAdult (≥18 years old) patients who underwent robot-assisted S2AI screw placement from 2017-2019 were reviewed. All surgeries used the same proprietary robotic guidance system, Mazor X (Mazor Robotics Ltd).

resultsA total of 65 screws were assessed in 31 patients. The mean follow-up ± standard deviation was 362±190 days (minimum was 90 days). The mean age was 61.1±11 years old, and 54.8% (n=17) of patients were female. Nearly half of the patients had a primary diagnosis of degenerative scoliosis (48.4%, n=15). Other diagnosis included pseudarthrosis (22.6%, n=7), degenerative disc disease (16.1%, n=5), and high-grade spondylolisthesis (12.9%, n=4). The mean length and diameter of screws were 84.6±6.1 mm and 8.4±0.7, respectively. The mean axial and sagittal angles were 50.0±6.3 and 24.0±10.5, respectively. The overall screw accuracy was 93.8% (n=61). There were four iliac cortex breaches (anterior =3, inferior 1) with a mean breach distance of 3.5±3.2. No statistically significant differences in screw length, diameter, axial angle, and sagittal angle were observed between screws with and without a breach. No intraoperative neurologic, vascular, or visceral complications from the S2AI screw were observed. No post-discharge wound complications, screw prominence issues, or revision of S2AI screws were observed during the study's follow-up period.

conclusionsRobot-assisted S2AI screw placement was found to be safe and accurate in this multicenter study. This is largely attributed to the versatility of the robotic guidance software that allows for detailed and precise preoperative and intraoperative planning.

Indexed as

Robot-assisted spine surgeryrobotic spine surgeryS2 alar-iliac (S2AI)sacral alar iliac screwspinopelvic fusion

Identifiers

PMID34734137
PMCPMC8511558

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.