ArticleBMC pediatrics2021
Treatment device for neonatal birth asphyxia related Hypoxic Ischemic Encephalopathy.
Article in BMC pediatrics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.
- Incidence of neonatal asphyxia and associated risk factors: a systematic review and cumulative meta-analysis.BMC pediatrics · 2025Pooled it
- Therapeutic Hypothermia and Recombinant Erythropoietin Mitigate Brain Microvascular Endothelial Cell Dysfunction via Modulating the Pentose Phosphate Pathway.Journal of molecular neuroscience : MN · 2025Article
- Identification of Novel Biomarkers Using Serum and Urinary Proteomics for Early Detection of Hypoxic Ischemic Encephalopathy.Indian journal of clinical biochemistry : IJCB · 2024Article
- Stem Cell Therapy in Neonatal Hypoxic-Ischemic Encephalopathy and Cerebral Palsy: a Bibliometric Analysis and New Strategy.Molecular neurobiology · 2024Review
- Determinants of speech and language delay among children aged 12 months to 12 years at Yekatit 12 Hospital, Addis Ababa, Ethiopia: a case-control study.BMC pediatrics · 2024Article
- Hypoxic-ischaemic encephalopathy based on clinical signs and symptoms and associated factors among neonates, Southern Ethiopian public hospitals: a case-control study.Annals of medicine and surgery (2012) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBirth asphyxia is a leading cause of neonatal brain injury, morbidity, and mortality globally. It leads to a multi-organ dysfunction in the neonate and to a neurological dysfunction called Hypoxic Ischemic Encephalopathy (HIE). Cooling therapy is commonly used to slow or stop the damaging effects of birth asphyxia. However, most of the cooling devices used in the healthcare facility do not have a rewarming functionality after cooling therapy. A separate rewarming device, usually a radiant warmer or incubator is used to rewarm the infant after therapy, causing additional burden to the healthcare system and infant families. The objective of this project was, therefore, to design and develop a cost-effective and efficient total body cooling and rewarming device.
methodsOur design includes two water reservoirs that operate by pumping cold and warm sterile water to a mattress. After decreasing the infant's core body temperature to 33.5 °C, the system is designed to maintain it for 72 h. Feedback for temperature regulation is provided by the rectal and mattress temperature sensors. Once the cooling therapy is completed, the system again rewarms the water inside the mattress and gradually increases the neonate temperature to 36.5-37 °C. The water temperature sensors' effectiveness was evaluated by adding 1000 ml of water to the reservoir and cooling and warming to the required level of temperature using Peltier. Then a digital thermometer was used as a gold standard to compare with the sensor's readings. This was performed for five iterations.
resultsThe prototype was built and gone through different tests and iterations. The proposed device was tested for accuracy, cost-effectiveness and easy to use. Ninety-three point two percent accuracy has been achieved for temperature sensor measurement, and the prototype was built only with a component cost of less than 200 USD. This is excluding design, manufacturing, and other costs.
conclusionA device that can monitor and regulate the neonate core body temperature at the neuroprotective range is designed and developed. This is achieved by continuous monitoring and regulation of the water reservoirs, mattress, and rectal temperatures. The device also allows continuous monitoring of the infant's body temperature, mattress temperature, reservoir temperature, and pulse rate. The proposed device has the potential to play a significant role in reducing neonatal brain injury and death due to HIE, especially in low resource settings, where the expertise and the means are scarce.