Evidence map›Paper›PMID 34731302›Full record

ArticleSurgical endoscopy2022

Characterisation of trocar associated gas leaks during laparoscopic surgery.

Daniel Robertson, Frank Sterke, Willem van Weteringen, Alberto Arezzo, Yoav Mintz, Felix Nickel, Technology committee of the European Association for Endoscopic Surgery (EAES), Tim Horeman

Erratum issuedAbstract read
In one paragraph

Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Clear Vision, Clear Savings: Enhancing Efficiency in Minimally Invasive Surgery.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Daniel Robertson *Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, TU Delft, Mekelweg 2, 2628 CD, Delft, The Netherlands. p.d.robertson@tudelft.nl.ORCID http://orcid.org/0000-0002-3373-5113
Frank Sterke *Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, TU Delft, Mekelweg 2, 2628 CD, Delft, The Netherlands.ORCID http://orcid.org/0000-0002-7194-491X
Willem van WeteringenDepartment of Paediatric Surgery, Erasmus MC Sophia Children's Hospital, University Medical Center Rotterdam, Rotterdam, The Netherlands.ORCID http://orcid.org/0000-0003-2667-3169
Alberto ArezzoDepartment of Surgical Sciences, University of Torino, Torino, Italy.ORCID http://orcid.org/0000-0002-2110-4082
Yoav MintzDepartment of General Surgery, Hadassah Hebrew University Medical Center, Jerusalem, Israel.ORCID http://orcid.org/0000-0002-5101-7449
Felix NickelDepartment of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Im, Neuenheimer Feld 420, 69120, Heidelberg, Germany.ORCID http://orcid.org/0000-0001-6066-8238
Technology committee of the European Association for Endoscopic Surgery (EAES)
Tim HoremanDepartment of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, TU Delft, Mekelweg 2, 2628 CD, Delft, The Netherlands.ORCID http://orcid.org/0000-0002-8527-4486

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO

methodsA model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery.

resultsTwenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage.

conclusionsWe propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO

Indexed as

Carbon DioxideLaparoscopyEquipment FailureHumansSurgical InstrumentsCarbon DioxideCarbon dioxideGas leakLaparoscopic equipmentSurgical safetySurgical smoke

Identifiers

PMID34731302
PMCPMC8565170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.