Evidence map›Paper›PMID 34725027›Full record

ArticleJournal of the American Association for Laboratory Animal Science : JAALAS2021

Point-of-Care Glucose and Lipid Profile Measures Using a Human Point-of-Care Device in Mouse Models of Type 2 Diabetes Mellitus, Aging, and Alzheimer Disease.

Brendan J Smyth, Rachel S Polaski, Anton Safer, Flint A Boettcher, Dawn Konrad-Martin, Michael Anne Gratton

Open access · greenAbstract read
In one paragraph

Article in Journal of the American Association for Laboratory Animal Science : JAALAS, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 90% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Brendan J SmythDepartment of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri.
Rachel S PolaskiVA RR&D National Center for Rehabilitative Auditory Research, VA Portland Health Care System, Portland, Oregon.
Anton SaferInstitute of Global Health (HIGH), Heidelberg University, Heidelberg, Germany.
Flint A BoettcherDepartment of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri.
Dawn Konrad-MartinVA RR&D National Center for Rehabilitative Auditory Research, VA Portland Health Care System, Portland, Oregon.
Michael Anne GrattonDepartment of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri.
Washington University in St. Louis · USVA Portland Health Care System · USHeidelberg University · DE

Funding

Longitudinal Changes in Auditory Function Among Veterans with DiabetesI01RX000559 · VA · PORTLAND VA MEDICAL CENTER · PI DILLE, MARILYN F., KONRAD-MARTIN, DAWN L · 2012 to 2020
–
RRD VA I01 RX000559
6 · The paper itself

Abstract

A point-of-care (POC) device to measure mouse glucose and lipid profiles is an important unmet need for cost-effective, immediate decision making in research. We compared metabolic analyte profiles obtained using a human clinical POC device with those from a veterinary laboratory chemical analyzer (LCA). Unfasted terminal blood samples were obtained by cardiac puncture from C57Bl/6J mice used in a diet-induced obesity model of type 2 diabetes mellitus; age-matched C57Bl/6J controls; a transgenic mouse model of Alzheimer's disease on a C57BL/6J background (16 wk old); and aged C57BL/6J mice (24 to 60 wk old). Aliquots of the blood were immediately assayed onsite using the POC device. Corresponding serum aliquots were sent analyzed by LCA. Measures from the POC and LCA devices were compared by using the Bland-Altman and Passing-Bablok methods. Of a total of 40 aliquots, LCA results were within reported reference ranges for each model. POC results that fell beyond the device range were excluded from the analyses. The coefficient of determination and Passing-Bablok analysis demonstrated that POC glucose and HDL had the best agreement with LCA. The Bland-Altman analysis found no value-dependent bias in glucose and no significant bias in HDL. The remaining lipid analytes (cholesterol and triglyceride) showed significant bias. Until an improved, validated mouse POC device with lipid profile capability is available, the POC device that we tested appears adequate for screening glucose and HDL in mouse blood. Disadvantages of this clinical POC device are the narrow human ranges relative to ranges found in mice and its limited precision as compared with the LCA. This study demonstrates that when the samples are within the device range limits, this human POC device can accurately track metabolic syndrome and be used to compare patterns in glucose and HDL.

Indexed as

Alzheimer DiseaseDiabetes Mellitus, Type 2AgedAgingAnimalsGlucoseHumansLipidsMiceMice, Inbred C57BLPoint-of-Care SystemsGlucoseLipids

Identifiers

PMID34725027
PMCPMC8628525
OpenAlexW3208356159

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.