Evidence map›Paper›PMID 34724939›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2021

Dark blood cardiovascular magnetic resonance of the heart, great vessels, and lungs using electrocardiographic-gated three-dimensional unbalanced steady-state free precession.

Robert R Edelman, Nondas Leloudas, Jianing Pang, Ioannis Koktzoglou

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. 2021-2022 state of our JCMR.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Robert R EdelmanDepartment of Radiology, Northshore University HealthSystem, Evanston, IL, USA. redelman999@gmail.com.ORCID 0000-0002-0013-8822
Nondas LeloudasDepartment of Radiology, Northshore University HealthSystem, Evanston, IL, USA.
Jianing PangSiemens Medical Solutions USA Inc., Chicago, IL, USA.
Ioannis KoktzoglouDepartment of Radiology, Northshore University HealthSystem, Evanston, IL, USA.
NorthShore University HealthSystem · USNorthwestern University · US

Funding

Improved Detection of Cerebral Metastases using a using a Novel T1 Relaxation-Enhanced Steady-State (T1RESS) MRI TechniqueR01CA263091 · NCI · ENDEAVOR HEALTH CLINICAL OPERATIONS · PI Robert R. Edelman · 2022 to 2026
$2.3M
Nonenhanced 3T QISS MR Angiography of the Peripheral ArteriesR01HL130093 · NHLBI · ENDEAVOR HEALTH CLINICAL OPERATIONS · PI EDELMAN, ROBERT R. · 2016 to 2019
$2.0M
Pre-Procedural Evaluation of High-Risk Patients using Next-Generation Radial QISSR01HL137920 · NHLBI · ENDEAVOR HEALTH CLINICAL OPERATIONS · PI EDELMAN, ROBERT R. · 2018 to 2021
$1.5M
NCI NIH HHS R01 CA263091NHLBI NIH HHS R01 HL130093NHLBI NIH HHS R01 HL137920NIH HHS HL130093NIH HHS HL137920
6 · The paper itself

Abstract

backgroundRecently, we reported a novel neuroimaging technique, unbalanced T1 Relaxation-Enhanced Steady-State (uT MAIN BODY: The study was approved by the hospital institutional review board. Thirty-one adult subjects were imaged at 1.5 T, including 5 healthy adult subjects and 26 patients (44 to 86 years, 10 female) undergoing a clinically indicated CMR. Breath-holding was used in 29 subjects and navigator gating in 2 subjects. For breath-hold acquisitions, the 3D uSSFP pulse sequence used a high sampling bandwidth, asymmetric readout, and single-shot along the phase-encoding direction, while 3 shots were acquired for navigator-gated scans. To minimize signal dephasing from bulk motion, electrocardiographic (ECG) gating was used to synchronize the data acquisition to the diastolic phase of the cardiac cycle. To further reduce motion sensitivity, the moment of the dephasing gradient was set to one-fifth of the moment of the readout gradient. Image quality using 3D uSSFP was good-to-excellent in all subjects. The blood pool signal in the thoracic aorta was uniformly suppressed with sharp delineation of the aortic wall including two cases of ascending aortic aneurysm and two cases of aortic dissection. Compared with variable flip angle 3D turbo spin-echo, 3D uSSFP showed improved aortic wall sharpness. It was also more efficient, permitting the acquisition of 24 slices in each breath-hold versus 16 slices with 3D turbo spin-echo and a single slice with dual inversion 2D turbo spin-echo. In addition, lung and mediastinal lesions appeared highly conspicuous compared with the low blood pool signals within the heart and blood vessels. In two subjects, navigator-gated 3D uSSFP provided excellent delineation of cardiac morphology in double oblique multiplanar reformations.

conclusionIn this pilot study, we have demonstrated the feasibility of using ECG-gated 3D uSSFP for dark blood imaging of the heart, great vessels, and lungs. Further study will be required to fully optimize the technique and to assess clinical utility.

Indexed as

Image Interpretation, Computer-AssistedMagnetic Resonance AngiographyAdultElectrocardiographyFemaleHumansImaging, Three-DimensionalLungMagnetic Resonance SpectroscopyPilot ProjectsPredictive Value of TestsBreath-holdCardiacDark blood imagingElectrocardiographic (ECG) gatingGreat vesselsLungsMagnetic resonanceNavigator gatingT1 relaxation-enhanced steady-stateUnbalanced 3D steady-state free precession

Identifiers

PMID34724939
PMCPMC8559409
OpenAlexW3208389388

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.