Evidence map›Paper›PMID 34724585›Full record

ArticleSurgical endoscopy2022

Intraoperative dynamics of workflow disruptions and surgeons' technical performance failures: insights from a simulated operating room.

Amelie Koch, Aljoscha Kullmann, Philipp Stefan, Tobias Weinmann, Sebastian F Baumbach, Marc Lazarovici, Matthias Weigl

Open access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Amelie KochInstitute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Munich, Germany. amelie.koch@med.uni-muenchen.de.ORCID http://orcid.org/0000-0002-4389-2868
Aljoscha KullmannChair for Computer Aided Medical Procedures & Augmented Reality, Department of Informatics / I 16, Technical University of Munich, Munich, Germany.
Philipp StefanChair for Computer Aided Medical Procedures & Augmented Reality, Department of Informatics / I 16, Technical University of Munich, Munich, Germany.ORCID http://orcid.org/0000-0003-4386-6456
Tobias WeinmannInstitute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Munich, Germany.ORCID http://orcid.org/0000-0002-4582-5191
Sebastian F BaumbachDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Marc LazaroviciInstitute for Emergency Medicine and Management in Medicine (INM), University Hospital, LMU Munich, Munich, Germany.
Matthias WeiglInstitute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Munich, Germany.ORCID http://orcid.org/0000-0003-2408-1725
Ludwig-Maximilians-Universität München · DETechnical University of Munich · DEUniversity of Bonn · DELMU Klinikum · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFlow disruptions (FD) in the operating room (OR) have been found to adversely affect the levels of stress and cognitive workload of the surgical team. It has been concluded that frequent disruptions also lead to impaired technical performance and subsequently pose a risk to patient safety. However, respective studies are scarce. We therefore aimed to determine if surgical performance failures increase after disruptive events during a complete surgical intervention.

methodsWe set up a mixed-reality-based OR simulation study within a full-team scenario. Eleven orthopaedic surgeons performed a vertebroplasty procedure from incision to closure. Simulations were audio- and videotaped and key surgical instrument movements were automatically tracked to determine performance failures, i.e. injury of critical tissue. Flow disruptions were identified through retrospective video observation and evaluated according to duration, severity, source, and initiation. We applied a multilevel binary logistic regression model to determine the relationship between FDs and technical performance failures. For this purpose, we compared FDs in one-minute intervals before performance failures with intervals without subsequent performance failures.

resultsAverage simulation duration was 30:02 min (SD = 10:48 min). In 11 simulated cases, 114 flow disruption events were observed with a mean hourly rate of 20.4 (SD = 5.6) and substantial variation across FD sources. Overall, 53 performance failures were recorded. We observed no relationship between FDs and likelihood of immediate performance failures: Adjusted odds ratio = 1.03 (95% CI 0.46-2.30). Likewise, no evidence could be found for different source types of FDs.

conclusionOur study advances previous methodological approaches through the utilisation of a mixed-reality simulation environment, automated surgical performance assessments, and expert-rated observations of FD events. Our data do not support the common assumption that FDs adversely affect technical performance. Yet, future studies should focus on the determining factors, mechanisms, and dynamics underlying our findings.

Indexed as

Operating RoomsSurgeonsHumansRetrospective StudiesWorkflowWorkloadFlow disruptionsPatient safetySurgical simulationTechnical performance

Identifiers

PMID34724585
PMCPMC9085674
OpenAlexW3208742866

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.